{"tenant_id": "brim", "items": [{"critical_rms": "4.5", "component": "Drive Motor Bearing", "asset_name": "Drive Motor Bearing", "GSI1_SK": "METADATA", "part_number": "", "critical_temp": "70", "PK": "TENANT#brim", "warning_temp": "51", "warning_rms": "2.8", "GSI1_PK": "ASSET#brim_1", "machine_id": "brim_1", "metric_thresholds": {"temperature": {"critical": "70", "warning": "51", "unit": "\u00b0C"}, "vibration_rms": {"critical": "4.5", "warning": "2.8", "unit": "mm/s"}}, "SK": "ASSET#brim_1"}, {"critical_rms": "4.5", "component": "Conveyor Roller Bearing", "asset_name": "Brim 2 (Filleting Line Conveyor)", "GSI1_SK": "METADATA", "part_number": "SKF-6308-2RS", "critical_temp": "70", "PK": "TENANT#brim", "warning_temp": "50", "warning_rms": "2.8", "GSI1_PK": "ASSET#brim_2", "SK": "ASSET#brim_2"}, {"role": "MAINTENANCE_ENGINEER", "is_on_duty": true, "phone_number": "+3548622107", "receive_email": true, "receive_sms": true, "PK": "TENANT#brim", "email": "frimann.rafnsson@gmail.com", "SK": "CONTACT#frimannrafns"}, {"plant_id": "nordurgardur", "department_name": "M\u00f3ttaka", "GSI1_SK": "DEPT#mottaka", "department_id": "mottaka", "description": "M\u00f3ttaka", "PK": "TENANT#brim", "GSI1_PK": "PLANT#nordurgardur", "SK": "DEPT#mottaka"}, {"plant_id": "nordurgardur", "GSI1_SK": "LINE#mottokulina", "line_id": "mottokulina", "department_id": "mottaka", "PK": "TENANT#brim", "line_name": "M\u00f3tt\u00f6kul\u00edna", "GSI1_PK": "DEPT#mottaka", "SK": "LINE#mottokulina"}, {"duration_ms": "9964.107762999995", "entity_type": "LLM_INVOCATION_LOG", "status": "SUCCESS", "timestamp": "2026-09-30T13:53:20.969924+00:00", "ttl": "1793368400", "model_id": "eu.anthropic.claude-haiku-4-5-20251001-v1:0", "asset_id": "brim_1", "tenant_id": "brim", "GSI1_SK": "LLMLOG#2026-09-30T13:53:20.969924+00:00", "parsed_synthesis": {"action_plan": ["1. **LOTO & SAFETY**: Turn Main Infeed Conveyor Breaker Switch 4B (Panel M1) to OFF and attach physical padlock. Verify zero-energy state with calibrated multimeter on motor terminals U1, V1, W1 (0V AC). Place mechanical lock wedge under infeed belt drive sprocket [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "2. **SPARE PARTS**: Procure Marel Drive Drum Bearing Kit No. **M-GRD-6205-KIT** containing SKF **6205-2RSH** deep groove ball bearing (25\u00d752\u00d715 mm), stainless steel labyrinth splash deflector disc **M-DEF-25-SS**, and two high-temp EPDM O-rings (48.0\u00d72.5 mm) from **Shelf B-04** [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "3. **REMOVAL & REPLACEMENT**: Remove bearing housing end-cap fasteners (4\u00d7 M8\u00d725) using cross-diagonal pattern. Extract worn SKF 6205-2RSH bearing and inspect shaft for radial runout (tolerance < **0.04 mm**). Clean bearing cavity with food-grade solvent, install new bearing with stainless splash disc seated flush at **1.0 mm clearance** for 80-bar washdown protection, and apply **Mobil SHC 627** (ISO VG 460 synthetic, NSF H1) lubricant [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "4. **TORQUES & ALIGNMENT**: Torque bearing housing end-cap fasteners to **24 Nm** in cross-diagonal pattern. Verify motor foot mounting bolts (4\u00d7 M12\u00d750 A4-80) at **75 Nm**. Perform optical laser alignment check; radial offset must be < **0.05 mm** [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "5. **STARTUP & VERIFICATION**: Remove LOTO padlock and mechanical wedge. Run infeed conveyor at full speed for 15 minutes under no-load condition. Measure baseline vibration RMS with calibrated sensor (target < **2.5 mm/s**). Document final vibration reading, confirm smooth operation, and sign off work order completion."], "title": "[P2] Brim 1 (Main Grader Drive Motor) \u2013 Drive Motor Bearing Replacement (SKF-6205-2RSH)", "spare_part": {"quantity": "1", "part_number": "M-GRD-6205-KIT (Contains SKF 6205-2RSH)", "shelf_location": "Shelf B-04", "component": "Drive Motor Bearing Assembly Kit"}, "ai_diagnostics": "Vibration RMS at 3.70 mm/s exceeds safe operating threshold, indicating advanced bearing wear on the infeed conveyor drive drum. Remaining useful life is 1.8 weeks; immediate replacement required to prevent catastrophic failure and production bottleneck. No historical maintenance records exist for this bearing assembly, suggesting first-time failure or extended service interval.", "safety_precautions": "LOTO isolation is mandatory before bearing removal; verify zero voltage on motor terminals U1, V1, W1 with calibrated multimeter. Ensure stainless splash deflector disc M-DEF-25-SS is installed at exactly 1.0 mm clearance to protect bearing from high-pressure sanitation washdown (80 bar)."}, "prompt": "You are PREDIXA's Senior Reliability & Industrial Maintenance AI Engineer for fish processing machinery and maritime equipment.\nAnalyze the following machinery context, historical repairs, OEM service manual specifications, and live telemetry to formulate a precision corrective maintenance work order.\n\n=== EQUIPMENT CONTEXT ===\n- Asset: Brim 1 (Main Grader Drive Motor) (ID: brim_1)\n- Component: Drive Motor Bearing\n- Priority: P2\n- Origin: SENSOR\n- Floor Operator Notes: None\n\n=== LIVE TELEMETRY & PREDICTIVE METRICS ===\n{\n  \"sensor_id\": \"b0d9b54f3558\",\n  \"value\": 3.7047958374023438,\n  \"unit\": \"mm/s\",\n  \"technical_condition\": \"WARNING\",\n  \"operational_severity\": \"BOTTLENECK\",\n  \"rul_weeks\": 1.8,\n  \"temperature\": null,\n  \"vibration_rms\": 3.7047958374023438,\n  \"part_number\": \"SKF-6205-2RSH\",\n  \"shelf_location\": \"Shelf B-04\"\n}\n\n=== MAINTENANCE HISTORY (PAST WORK ORDERS) ===\nNo previous work orders or fleet records recorded for part SKF-6205-2RSH.\n\n=== OEM TECHNICAL SERVICE MANUAL (FACTORY SPECIFICATIONS) ===\n=== OEM MANUAL SOURCE: M2000 Weight Grader User Manual | Section: Section 3.2: Infeed Conveyor & Drive Drum Subassembly | Page: 44 ===\n[OEM MANUAL REF: M2000 Weight Grader User Manual, Section 3.2, Page 44]\nMAREL M2000 WEIGHT GRADER - INFEED CONVEYOR & DRIVE DRUM SUBASSEMBLY\nTarget Components: Infeed Conveyor Drive Drum Bearing (Node b0d9b54f3558), Drive Motor Drivetrain.\nOEM Spare Part Kit: Marel Drive Drum Bearing Kit No. M-GRD-6205-KIT (Contains: 1x SKF 6205-2RSH Deep Groove Ball Bearing 25x52x15mm, 1x Stainless Steel Labyrinth Splash Deflector Disc M-DEF-25-SS, 2x High-Temp EPDM O-Rings 48.0x2.5mm).\nWarehouse Storage: Shelf B-04 (Drive Motors & Conveyors Section).\nFastener Torque Specifications:\n- Motor Foot Mounting Bolts (4x M12x50 A4-80): 75 Nm.\n- Bearing Housing End-Cap Fasteners (4x M8x25): 24 Nm (Cross-diagonal torque pattern).\n- Conveyor Infeed Belt Tensioner Bolts: 35 Nm.\nPrecision Alignment:\n- Shaft Radial Runout: < 0.04 mm.\n- Optical Laser Alignment Radial Offset: < 0.05 mm.\nWashdown Sanitation Protection:\n- During bearing replacement, ensure stainless splash disc M-DEF-25-SS is seated flush with 1.0 mm clearance to protect against 80-bar high-pressure sanitation washdown.\nApproved Food-Grade Lubricant: Mobil SHC 627 (ISO VG 460 Synthetic, NSF H1).\nSafety Lockout/Tagout (LOTO) Procedure:\n1. Turn Main Infeed Conveyor Breaker Switch 4B (Panel M1) to OFF and attach physical padlock.\n2. Verify zero-energy state with calibrated multimeter on motor terminals U1, V1, W1 (0V AC).\n3. Place mechanical lock wedge under infeed belt drive sprocket.\n\n---\n\n=== OEM MANUAL SOURCE: IPM XL-350 Hardware Manual.pdf | Section: Section 52: Maintenance & Service | Page: 52 ===\n[OEM MANUAL REF: IPM XL-350 Hardware Manual.pdf, Section 52: Maintenance & Service, Page 52]\nDrive belt \n \n46  \u2022  Parts Lists IPM XL350\n\n=== INSTRUCTIONS ===\nGenerate a structured, professional English work order for plant technicians.\nLANGUAGE REQUIREMENT: Every single word and field (title, ai_diagnostics, action_plan, spare_part, safety_precautions) MUST BE IN PURE ENGLISH. Under no circumstances generate Icelandic or any other non-English language.\nBREVITY & SPEED REQUIREMENT: Keep text dense, scannable, and concise. Each action step must be strictly 1-2 direct sentences without unnecessary introductory filler.\n\nCRITICAL GROUNDING & ANTI-HALLUCINATION RULES:\n1. HELPFUL FACTUAL GROUNDING: Incorporate factory specifications (LOTO isolators, part kit numbers, fastener torques, tolerances, page numbers) ONLY if they are explicitly present in the provided `=== OEM TECHNICAL SERVICE MANUAL ===` context.\n2. ABSOLUTELY NO HALLUCINATIONS OR GUESSING: If no OEM manual context is provided, or if a specific detail (like torque or page number) is not in the manual context, DO NOT invent or fabricate manual names, section numbers, or page numbers. Instead, provide clean standard industrial engineering steps without fabricated references.\n3. CITATION FORMAT: When referencing specifications from the provided OEM manual, append the exact citation from the source header (e.g. `[Ref: IPM XL-350 Hardware Manual, Sec 4.4.1, p. 88]`, `[Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44]`).\n\nFormat requirements:\n- \"ai_diagnostics\": Exactly 2-3 concise sentences stating the alarm condition, vibration/temperature values, RUL, and historical root cause.\n- \"action_plan\": EXACTLY 5 concise bullet points. Each bullet must start with a bolded header and use bolding for critical part codes, shelves, torques, and tolerances:\n  1. **LOTO & SAFETY**: Exact isolator switch, air dump valve, and mechanical locking pin [Ref: Manual Title, Section, Page if provided in manual context].\n  2. **SPARE PARTS**: Exact OEM kit number, component part number, and warehouse shelf location [Ref: Manual Title, Section, Page if provided in manual context].\n  3. **REMOVAL & REPLACEMENT**: Precision overhaul procedure, food-grade grease, and dial indicator inspection [Ref: Manual Title, Section, Page if provided in manual context].\n  4. **TORQUES & ALIGNMENT**: Exact bolt torque values (Nm in bold) and laser/dial tolerances [Ref: Manual Title, Section, Page if provided in manual context].\n  5. **STARTUP & VERIFICATION**: Run-in duration, baseline vibration RMS target (< 2.5 mm/s), and sign-off verification.\n\nReturn ONLY valid JSON (enclosed in ```json ... ``` or as plain JSON) with the exact keys:\n{\n  \"title\": \"[P2] Brim 1 (Main Grader Drive Motor) - Specific corrective action\",\n  \"ai_diagnostics\": \"2-3 crisp sentences in pure English.\",\n  \"action_plan\": [\n    \"1. **LOTO & SAFETY**: ...\",\n    \"2. **SPARE PARTS**: ...\",\n    \"3. **REMOVAL & REPLACEMENT**: ...\",\n    \"4. **TORQUES & ALIGNMENT**: ...\",\n    \"5. **STARTUP & VERIFICATION**: ...\"\n  ],\n  \"spare_part\": {\n    \"component\": \"Drive Motor Bearing\",\n    \"part_number\": \"Exact OEM part number or kit code\",\n    \"shelf_location\": \"Warehouse Shelf location (e.g. Shelf B-04)\",\n    \"quantity\": 1\n  },\n  \"safety_precautions\": \"1-2 sentence safety or LOTO warning.\"\n}\n", "PK": "TENANT#brim", "error": "", "GSI1_PK": "ASSET#brim_1", "raw_response": "```json\n{\n  \"title\": \"[P2] Brim 1 (Main Grader Drive Motor) \u2013 Drive Motor Bearing Replacement (SKF-6205-2RSH)\",\n  \"ai_diagnostics\": \"Vibration RMS at 3.70 mm/s exceeds safe operating threshold, indicating advanced bearing wear on the infeed conveyor drive drum. Remaining useful life is 1.8 weeks; immediate replacement required to prevent catastrophic failure and production bottleneck. No historical maintenance records exist for this bearing assembly, suggesting first-time failure or extended service interval.\",\n  \"action_plan\": [\n    \"1. **LOTO & SAFETY**: Turn Main Infeed Conveyor Breaker Switch 4B (Panel M1) to OFF and attach physical padlock. Verify zero-energy state with calibrated multimeter on motor terminals U1, V1, W1 (0V AC). Place mechanical lock wedge under infeed belt drive sprocket [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].\",\n    \"2. **SPARE PARTS**: Procure Marel Drive Drum Bearing Kit No. **M-GRD-6205-KIT** containing SKF **6205-2RSH** deep groove ball bearing (25\u00d752\u00d715 mm), stainless steel labyrinth splash deflector disc **M-DEF-25-SS**, and two high-temp EPDM O-rings (48.0\u00d72.5 mm) from **Shelf B-04** [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].\",\n    \"3. **REMOVAL & REPLACEMENT**: Remove bearing housing end-cap fasteners (4\u00d7 M8\u00d725) using cross-diagonal pattern. Extract worn SKF 6205-2RSH bearing and inspect shaft for radial runout (tolerance < **0.04 mm**). Clean bearing cavity with food-grade solvent, install new bearing with stainless splash disc seated flush at **1.0 mm clearance** for 80-bar washdown protection, and apply **Mobil SHC 627** (ISO VG 460 synthetic, NSF H1) lubricant [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].\",\n    \"4. **TORQUES & ALIGNMENT**: Torque bearing housing end-cap fasteners to **24 Nm** in cross-diagonal pattern. Verify motor foot mounting bolts (4\u00d7 M12\u00d750 A4-80) at **75 Nm**. Perform optical laser alignment check; radial offset must be < **0.05 mm** [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].\",\n    \"5. **STARTUP & VERIFICATION**: Remove LOTO padlock and mechanical wedge. Run infeed conveyor at full speed for 15 minutes under no-load condition. Measure baseline vibration RMS with calibrated sensor (target < **2.5 mm/s**). Document final vibration reading, confirm smooth operation, and sign off work order completion.\"\n  ],\n  \"spare_part\": {\n    \"component\": \"Drive Motor Bearing Assembly Kit\",\n    \"part_number\": \"M-GRD-6205-KIT (Contains SKF 6205-2RSH)\",\n    \"shelf_location\": \"Shelf B-04\",\n    \"quantity\": 1\n  },\n  \"safety_precautions\": \"LOTO isolation is mandatory before bearing removal; verify zero voltage on motor terminals U1, V1, W1 with calibrated multimeter. Ensure stainless splash deflector disc M-DEF-25-SS is installed at exactly 1.0 mm clearance to protect bearing from high-pressure sanitation washdown (80 bar).\"\n}\n```", "epoch_ms": "1790776400969", "SK": "LLMLOG#2026-09-30T13:53:20.969924+00:00#brim_1_c4324c"}, {"duration_ms": "11794.717005999928", "entity_type": "LLM_INVOCATION_LOG", "timestamp": "2026-10-01T09:14:53.411706+00:00", "status": "ERROR", "ttl": "1793438093", "model_id": "eu.anthropic.claude-haiku-4-5-20251001-v1:0", "asset_id": "brim_1", "tenant_id": "brim", "GSI1_SK": "LLMLOG#2026-10-01T09:14:53.411706+00:00", "parsed_synthesis": {}, "prompt": "You are PREDIXA's Senior Reliability & Industrial Maintenance AI Engineer for fish processing machinery and maritime equipment.\nAnalyze the following machinery context, historical repairs, OEM service manual specifications, and live telemetry to formulate a precision corrective maintenance work order.\n\n=== EQUIPMENT CONTEXT ===\n- Asset: Brim 1 (Main Grader Drive Motor) (ID: brim_1)\n- Component: Drive Motor Bearing\n- Priority: P1\n- Origin: SENSOR\n- Floor Operator Notes: None\n\n=== LIVE TELEMETRY & PREDICTIVE METRICS ===\n{\n  \"sensor_id\": \"b0d9b54f3558\",\n  \"value\": 5.987548828125001,\n  \"unit\": \"mm/s\",\n  \"technical_condition\": \"ALARM\",\n  \"operational_severity\": \"BOTTLENECK\",\n  \"rul_weeks\": 0.0,\n  \"temperature\": null,\n  \"vibration_rms\": 5.987548828125001,\n  \"part_number\": \"SKF-6205-2RSH\",\n  \"shelf_location\": \"Shelf B-04\"\n}\n\n=== MAINTENANCE HISTORY (PAST WORK ORDERS) ===\n=== COMPONENT RELIABILITY INTELLIGENCE (Part: SKF-6205-2RSH | Metric: vibration_rms_z) ===\n\n\ud83d\udccd LAYER 1: LOCAL MACHINE INSTANCE REPAIRS (1 records)\n  \u2022 Common Root Causes: 'BEARING_WEAR' (1x)\n  [1] WO wo-1790776400977 (Brim 1 (Main Grader Drive Motor))\n      Root Cause: BEARING_WEAR\n      Technician Notes: \"Replaced Drive Motor Bearing (PN: SKF-6205-2RSH). Outer race inspected and confirmed baseline restored.\"\n      Outcome: FALSE_POSITIVE\n\n\ud83c\udfed LAYER 2: SISTER MACHINES (SAME MODEL IN THIS PLANT) (1 records)\n  \u2022 Common Root Causes: 'BEARING_WEAR' (1x)\n  [1] WO wo-1790776400977 (Brim 1 (Main Grader Drive Motor))\n      Root Cause: BEARING_WEAR\n      Technician Notes: \"Replaced Drive Motor Bearing (PN: SKF-6205-2RSH). Outer race inspected and confirmed baseline restored.\"\n      Outcome: FALSE_POSITIVE\n\n\ud83c\udfe2 LAYER 3: PLANT-WIDE COMPONENT HISTORY (1 records)\n  \u2022 Common Root Causes: 'BEARING_WEAR' (1x)\n  [1] WO wo-1790776400977 (Brim 1 (Main Grader Drive Motor))\n      Root Cause: BEARING_WEAR\n      Technician Notes: \"Replaced Drive Motor Bearing (PN: SKF-6205-2RSH). Outer race inspected and confirmed baseline restored.\"\n      Outcome: FALSE_POSITIVE\n\n\ud83c\udf10 LAYER 4: GLOBAL BENCHMARK (SAME MODEL ACROSS ALL TENANTS) (1 records)\n  \u2022 Common Root Causes: 'BEARING_WEAR' (1x)\n  [1] WO wo-1790776400977 (Brim 1 (Main Grader Drive Motor))\n      Root Cause: BEARING_WEAR\n      Technician Notes: \"Replaced Drive Motor Bearing (PN: SKF-6205-2RSH). Outer race inspected and confirmed baseline restored.\"\n      Outcome: FALSE_POSITIVE\n\n\ud83d\udd2c LAYER 5: GLOBAL COMPONENT FAILURE INTELLIGENCE (1 records)\n  \u2022 Common Root Causes: 'BEARING_WEAR' (1x)\n  [1] WO wo-1790776400977 (Brim 1 (Main Grader Drive Motor))\n      Root Cause: BEARING_WEAR\n      Technician Notes: \"Replaced Drive Motor Bearing (PN: SKF-6205-2RSH). Outer race inspected and confirmed baseline restored.\"\n      Outcome: FALSE_POSITIVE\n\n\u26a0\ufe0f MULTI-LAYER RECURRING DEFECT: Root cause 'BEARING_WEAR' detected across 5 repair instances across the fleet.\n\n=== OEM TECHNICAL SERVICE MANUAL (FACTORY SPECIFICATIONS) ===\n=== OEM MANUAL SOURCE: M2000 Weight Grader User Manual | Section: Section 3.2: Infeed Conveyor & Drive Drum Subassembly | Page: 44 ===\n[OEM MANUAL REF: M2000 Weight Grader User Manual, Section 3.2, Page 44]\nMAREL M2000 WEIGHT GRADER - INFEED CONVEYOR & DRIVE DRUM SUBASSEMBLY\nTarget Components: Infeed Conveyor Drive Drum Bearing (Node b0d9b54f3558), Drive Motor Drivetrain.\nOEM Spare Part Kit: Marel Drive Drum Bearing Kit No. M-GRD-6205-KIT (Contains: 1x SKF 6205-2RSH Deep Groove Ball Bearing 25x52x15mm, 1x Stainless Steel Labyrinth Splash Deflector Disc M-DEF-25-SS, 2x High-Temp EPDM O-Rings 48.0x2.5mm).\nWarehouse Storage: Shelf B-04 (Drive Motors & Conveyors Section).\nFastener Torque Specifications:\n- Motor Foot Mounting Bolts (4x M12x50 A4-80): 75 Nm.\n- Bearing Housing End-Cap Fasteners (4x M8x25): 24 Nm (Cross-diagonal torque pattern).\n- Conveyor Infeed Belt Tensioner Bolts: 35 Nm.\nPrecision Alignment:\n- Shaft Radial Runout: < 0.04 mm.\n- Optical Laser Alignment Radial Offset: < 0.05 mm.\nWashdown Sanitation Protection:\n- During bearing replacement, ensure stainless splash disc M-DEF-25-SS is seated flush with 1.0 mm clearance to protect against 80-bar high-pressure sanitation washdown.\nApproved Food-Grade Lubricant: Mobil SHC 627 (ISO VG 460 Synthetic, NSF H1).\nSafety Lockout/Tagout (LOTO) Procedure:\n1. Turn Main Infeed Conveyor Breaker Switch 4B (Panel M1) to OFF and attach physical padlock.\n2. Verify zero-energy state with calibrated multimeter on motor terminals U1, V1, W1 (0V AC).\n3. Place mechanical lock wedge under infeed belt drive sprocket.\n\n---\n\n=== OEM MANUAL SOURCE: IPM XL-350 Hardware Manual.pdf | Section: Section 52: Maintenance & Service | Page: 52 ===\n[OEM MANUAL REF: IPM XL-350 Hardware Manual.pdf, Section 52: Maintenance & Service, Page 52]\nDrive belt \n \n46  \u2022  Parts Lists IPM XL350\n\n=== INSTRUCTIONS ===\nGenerate a structured, professional English work order for plant technicians.\nLANGUAGE REQUIREMENT: Every single word and field (title, ai_diagnostics, action_plan, spare_part, safety_precautions) MUST BE IN PURE ENGLISH. Under no circumstances generate Icelandic or any other non-English language.\nBREVITY & SPEED REQUIREMENT: Keep text dense, scannable, and concise. Each action step must be strictly 1-2 direct sentences without unnecessary introductory filler.\n\nCRITICAL GROUNDING & ANTI-HALLUCINATION RULES:\n1. HELPFUL FACTUAL GROUNDING: Incorporate factory specifications (LOTO isolators, part kit numbers, fastener torques, tolerances, page numbers) ONLY if they are explicitly present in the provided `=== OEM TECHNICAL SERVICE MANUAL ===` context.\n2. ABSOLUTELY NO HALLUCINATIONS OR GUESSING: If no OEM manual context is provided, or if a specific detail (like torque or page number) is not in the manual context, DO NOT invent or fabricate manual names, section numbers, or page numbers. Instead, provide clean standard industrial engineering steps without fabricated references.\n3. CITATION FORMAT: When referencing specifications from the provided OEM manual, append the exact citation from the source header (e.g. `[Ref: IPM XL-350 Hardware Manual, Sec 4.4.1, p. 88]`, `[Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44]`).\n\nFormat requirements:\n- \"ai_diagnostics\": Exactly 2-3 concise sentences stating the alarm condition, vibration/temperature values, RUL, and historical root cause.\n- \"action_plan\": EXACTLY 5 concise bullet points. Each bullet must start with a bolded header and use bolding for critical part codes, shelves, torques, and tolerances:\n  1. **LOTO & SAFETY**: Exact isolator switch, air dump valve, and mechanical locking pin [Ref: Manual Title, Section, Page if provided in manual context].\n  2. **SPARE PARTS**: Exact OEM kit number, component part number, and warehouse shelf location [Ref: Manual Title, Section, Page if provided in manual context].\n  3. **REMOVAL & REPLACEMENT**: Precision overhaul procedure, food-grade grease, and dial indicator inspection [Ref: Manual Title, Section, Page if provided in manual context].\n  4. **TORQUES & ALIGNMENT**: Exact bolt torque values (Nm in bold) and laser/dial tolerances [Ref: Manual Title, Section, Page if provided in manual context].\n  5. **STARTUP & VERIFICATION**: Run-in duration, baseline vibration RMS target (< 2.5 mm/s), and sign-off verification.\n\nReturn ONLY valid JSON (enclosed in ```json ... ``` or as plain JSON) with the exact keys:\n{\n  \"title\": \"[P1] Brim 1 (Main Grader Drive Motor) - Specific corrective action\",\n  \"ai_diagnostics\": \"2-3 crisp sentences in pure English.\",\n  \"action_plan\": [\n    \"1. **LOTO & SAFETY**: ...\",\n    \"2. **SPARE PARTS**: ...\",\n    \"3. **REMOVAL & REPLACEMENT**: ...\",\n    \"4. **TORQUES & ALIGNMENT**: ...\",\n    \"5. **STARTUP & VERIFICATION**: ...\"\n  ],\n  \"spare_part\": {\n    \"component\": \"Drive Motor Bearing\",\n    \"part_number\": \"Exact OEM part number or kit code\",\n    \"shelf_location\": \"Warehouse Shelf location (e.g. Shelf B-04)\",\n    \"quantity\": 1\n  },\n  \"safety_precautions\": \"1-2 sentence safety or LOTO warning.\"\n}\n", "PK": "TENANT#brim", "error": "Expecting ',' delimiter: line 16 column 4 (char 2929)", "GSI1_PK": "ASSET#brim_1", "epoch_ms": "1790846093411", "raw_response": "```json\n{\n  \"title\": \"[P1] Brim 1 (Main Grader Drive Motor) \u2013 Drive Motor Bearing Replacement (SKF-6205-2RSH)\",\n  \"ai_diagnostics\": \"Live vibration telemetry reports 5.99 mm/s RMS (ALARM threshold exceeded), with RUL of 0.0 weeks indicating imminent bearing failure. Historical maintenance records show prior bearing replacement (WO wo-1790776400977) resulted in false positive, suggesting potential root cause misdiagnosis or inadequate shaft alignment/lubrication protocol. Current operational severity is BOTTLENECK; immediate corrective action required to prevent unplanned downtime.\",\n  \"action_plan\": [\n    \"1. **LOTO & SAFETY**: Turn Main Infeed Conveyor Breaker Switch **4B** (Panel M1) to OFF and attach physical padlock. Verify zero-energy state using calibrated multimeter on motor terminals U1, V1, W1 (confirm 0V AC). Place mechanical lock wedge under infeed belt drive sprocket. [Ref: M2000 Weight Grader User Manual, Section 3.2, Page 44]\",\n    \"2. **SPARE PARTS**: Procure Marel Drive Drum Bearing Kit No. **M-GRD-6205-KIT** (contains SKF **6205-2RSH** Deep Groove Ball Bearing 25\u00d752\u00d715 mm, stainless steel labyrinth splash deflector disc **M-DEF-25-SS**, and 2\u00d7 high-temp EPDM O-rings 48.0\u00d72.5 mm) from **Shelf B-04** (Drive Motors & Conveyors Section). [Ref: M2000 Weight Grader User Manual, Section 3.2, Page 44]\",\n    \"3. **REMOVAL & REPLACEMENT**: Remove bearing housing end-cap fasteners (4\u00d7 M8\u00d725) and extract failed bearing. Inspect shaft for spalling, corrosion, or radial runout exceeding **0.04 mm** using dial indicator; if runout detected, escalate for shaft replacement. Clean bearing bore with lint-free cloth. Install new SKF 6205-2RSH bearing, seat stainless splash disc **M-DEF-25-SS** flush with **1.0 mm clearance** to motor housing. Apply **Mobil SHC 627** (ISO VG 460 Synthetic, NSF H1) food-grade lubricant per OEM specification. [Ref: M2000 Weight Grader User Manual, Section 3.2, Page 44]\",\n    \"4. **TORQUES & ALIGNMENT**: Torque bearing housing end-cap fasteners (4\u00d7 M8\u00d725) to **24 Nm** using cross-diagonal pattern. Torque motor foot mounting bolts (4\u00d7 M12\u00d750 A4-80) to **75 Nm**. Perform optical laser alignment verification; confirm shaft radial offset **< 0.05 mm** and radial runout **< 0.04 mm**. [Ref: M2000 Weight Grader User Manual, Section 3.2, Page 44]\",\n    \"5. **STARTUP & VERIFICATION**: Remove LOTO padlock and mechanical wedge. Run Brim 1 at 50% speed for 10 minutes, then full speed for 15 minutes. Measure vibration RMS using sensor **b0d9b54f3558**; confirm baseline **< 2.5 mm/s**. Document post-repair vibration signature and technician sign-off in maintenance log. If vibration remains elevated, investigate motor misalignment or drivetrain coupling wear.\"\n  ],\n  \"spare_part\": {\n    \"component\": \"Drive Motor Bearing Kit (Infeed Conveyor Drive Drum)\",\n    \"part_number\": \"M-GRD-6205-KIT (Primary: SKF-6205-2RSH)\",\n    \"shelf_location\": \"Shelf B-04\",\n    \"quantity\": 1\n  },\n  \"safety_precautions\": \"CRITICAL: Execute full LOTO isolation per M2000 manual Section 3.2, Page 44 before", "SK": "LLMLOG#2026-10-01T09:14:53.411706+00:00#brim_1_17a6dd"}, {"duration_ms": "1", "entity_type": "LLM_INVOCATION_LOG", "timestamp": "2026-10-01T09:14:53.417779+00:00", "status": "FALLBACK", "ttl": "1793438093", "model_id": "deterministic_fallback", "asset_id": "brim_1", "tenant_id": "brim", "GSI1_SK": "LLMLOG#2026-10-01T09:14:53.417779+00:00", "parsed_synthesis": {"title": "[P1] Brim 1 (Main Grader Drive Motor) - Replace Drive Motor Bearing", "ai_diagnostics": "Telemetry monitoring on Brim 1 (Main Grader Drive Motor) (Drive Motor Bearing) on sensor b0d9b54f3558 detected elevated degradation (Vibration RMS: 5.99 mm/s). Remaining Useful Life (RUL) projection indicates ~0.0 weeks to failure. Prioritized as P1 to prevent unscheduled plant downtime.", "safety_precautions": "Ensure Lockout/Tagout (LOTO) protocol is verified before removing safety guarding or housing.", "spare_part": {"part_number": "SKF-6205-2RSH", "component": "Drive Motor Bearing", "quantity": "1", "shelf_location": "Shelf B-04"}, "action_plan": ["1. **LOTO & SAFETY**: Turn Main Infeed Conveyor Breaker Switch **4B** (Panel M1) to OFF, attach padlock, and verify 0V AC on motor terminals U1, V1, W1 [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "2. **SPARE PARTS**: Retrieve Marel Infeed Drive Drum Bearing Kit **M-GRD-6205-KIT** (SKF 6205-2RSH + Splash Deflector M-DEF-25-SS) from warehouse **Shelf B-04** [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "3. **REMOVAL & REPLACEMENT**: Disassemble infeed drum housing, inspect shaft runout (< 0.04 mm), seat splash disc with **1.0 mm** clearance, and apply Mobil SHC 627 food-grade grease [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "4. **TORQUES & ALIGNMENT**: Torque motor foot bolts (M12) to **75 Nm**, end-caps (M8) to **24 Nm**, and belt tensioners to **35 Nm**. Verify radial alignment < 0.05 mm [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "5. **STARTUP & VERIFICATION**: Remove LOTO, run empty for 10 minutes, and verify Treon vibration RMS drops below 2.5 mm/s on sensor b0d9b54f3558."]}, "prompt": "You are PREDIXA's Senior Reliability & Industrial Maintenance AI Engineer for fish processing machinery and maritime equipment.\nAnalyze the following machinery context, historical repairs, OEM service manual specifications, and live telemetry to formulate a precision corrective maintenance work order.\n\n=== EQUIPMENT CONTEXT ===\n- Asset: Brim 1 (Main Grader Drive Motor) (ID: brim_1)\n- Component: Drive Motor Bearing\n- Priority: P1\n- Origin: SENSOR\n- Floor Operator Notes: None\n\n=== LIVE TELEMETRY & PREDICTIVE METRICS ===\n{\n  \"sensor_id\": \"b0d9b54f3558\",\n  \"value\": 5.987548828125001,\n  \"unit\": \"mm/s\",\n  \"technical_condition\": \"ALARM\",\n  \"operational_severity\": \"BOTTLENECK\",\n  \"rul_weeks\": 0.0,\n  \"temperature\": null,\n  \"vibration_rms\": 5.987548828125001,\n  \"part_number\": \"SKF-6205-2RSH\",\n  \"shelf_location\": \"Shelf B-04\"\n}\n\n=== MAINTENANCE HISTORY (PAST WORK ORDERS) ===\n=== COMPONENT RELIABILITY INTELLIGENCE (Part: SKF-6205-2RSH | Metric: vibration_rms_z) ===\n\n\ud83d\udccd LAYER 1: LOCAL MACHINE INSTANCE REPAIRS (1 records)\n  \u2022 Common Root Causes: 'BEARING_WEAR' (1x)\n  [1] WO wo-1790776400977 (Brim 1 (Main Grader Drive Motor))\n      Root Cause: BEARING_WEAR\n      Technician Notes: \"Replaced Drive Motor Bearing (PN: SKF-6205-2RSH). Outer race inspected and confirmed baseline restored.\"\n      Outcome: FALSE_POSITIVE\n\n\ud83c\udfed LAYER 2: SISTER MACHINES (SAME MODEL IN THIS PLANT) (1 records)\n  \u2022 Common Root Causes: 'BEARING_WEAR' (1x)\n  [1] WO wo-1790776400977 (Brim 1 (Main Grader Drive Motor))\n      Root Cause: BEARING_WEAR\n      Technician Notes: \"Replaced Drive Motor Bearing (PN: SKF-6205-2RSH). Outer race inspected and confirmed baseline restored.\"\n      Outcome: FALSE_POSITIVE\n\n\ud83c\udfe2 LAYER 3: PLANT-WIDE COMPONENT HISTORY (1 records)\n  \u2022 Common Root Causes: 'BEARING_WEAR' (1x)\n  [1] WO wo-1790776400977 (Brim 1 (Main Grader Drive Motor))\n      Root Cause: BEARING_WEAR\n      Technician Notes: \"Replaced Drive Motor Bearing (PN: SKF-6205-2RSH). Outer race inspected and confirmed baseline restored.\"\n      Outcome: FALSE_POSITIVE\n\n\ud83c\udf10 LAYER 4: GLOBAL BENCHMARK (SAME MODEL ACROSS ALL TENANTS) (1 records)\n  \u2022 Common Root Causes: 'BEARING_WEAR' (1x)\n  [1] WO wo-1790776400977 (Brim 1 (Main Grader Drive Motor))\n      Root Cause: BEARING_WEAR\n      Technician Notes: \"Replaced Drive Motor Bearing (PN: SKF-6205-2RSH). Outer race inspected and confirmed baseline restored.\"\n      Outcome: FALSE_POSITIVE\n\n\ud83d\udd2c LAYER 5: GLOBAL COMPONENT FAILURE INTELLIGENCE (1 records)\n  \u2022 Common Root Causes: 'BEARING_WEAR' (1x)\n  [1] WO wo-1790776400977 (Brim 1 (Main Grader Drive Motor))\n      Root Cause: BEARING_WEAR\n      Technician Notes: \"Replaced Drive Motor Bearing (PN: SKF-6205-2RSH). Outer race inspected and confirmed baseline restored.\"\n      Outcome: FALSE_POSITIVE\n\n\u26a0\ufe0f MULTI-LAYER RECURRING DEFECT: Root cause 'BEARING_WEAR' detected across 5 repair instances across the fleet.\n\n=== OEM TECHNICAL SERVICE MANUAL (FACTORY SPECIFICATIONS) ===\n=== OEM MANUAL SOURCE: M2000 Weight Grader User Manual | Section: Section 3.2: Infeed Conveyor & Drive Drum Subassembly | Page: 44 ===\n[OEM MANUAL REF: M2000 Weight Grader User Manual, Section 3.2, Page 44]\nMAREL M2000 WEIGHT GRADER - INFEED CONVEYOR & DRIVE DRUM SUBASSEMBLY\nTarget Components: Infeed Conveyor Drive Drum Bearing (Node b0d9b54f3558), Drive Motor Drivetrain.\nOEM Spare Part Kit: Marel Drive Drum Bearing Kit No. M-GRD-6205-KIT (Contains: 1x SKF 6205-2RSH Deep Groove Ball Bearing 25x52x15mm, 1x Stainless Steel Labyrinth Splash Deflector Disc M-DEF-25-SS, 2x High-Temp EPDM O-Rings 48.0x2.5mm).\nWarehouse Storage: Shelf B-04 (Drive Motors & Conveyors Section).\nFastener Torque Specifications:\n- Motor Foot Mounting Bolts (4x M12x50 A4-80): 75 Nm.\n- Bearing Housing End-Cap Fasteners (4x M8x25): 24 Nm (Cross-diagonal torque pattern).\n- Conveyor Infeed Belt Tensioner Bolts: 35 Nm.\nPrecision Alignment:\n- Shaft Radial Runout: < 0.04 mm.\n- Optical Laser Alignment Radial Offset: < 0.05 mm.\nWashdown Sanitation Protection:\n- During bearing replacement, ensure stainless splash disc M-DEF-25-SS is seated flush with 1.0 mm clearance to protect against 80-bar high-pressure sanitation washdown.\nApproved Food-Grade Lubricant: Mobil SHC 627 (ISO VG 460 Synthetic, NSF H1).\nSafety Lockout/Tagout (LOTO) Procedure:\n1. Turn Main Infeed Conveyor Breaker Switch 4B (Panel M1) to OFF and attach physical padlock.\n2. Verify zero-energy state with calibrated multimeter on motor terminals U1, V1, W1 (0V AC).\n3. Place mechanical lock wedge under infeed belt drive sprocket.\n\n---\n\n=== OEM MANUAL SOURCE: IPM XL-350 Hardware Manual.pdf | Section: Section 52: Maintenance & Service | Page: 52 ===\n[OEM MANUAL REF: IPM XL-350 Hardware Manual.pdf, Section 52: Maintenance & Service, Page 52]\nDrive belt \n \n46  \u2022  Parts Lists IPM XL350\n\n=== INSTRUCTIONS ===\nGenerate a structured, professional English work order for plant technicians.\nLANGUAGE REQUIREMENT: Every single word and field (title, ai_diagnostics, action_plan, spare_part, safety_precautions) MUST BE IN PURE ENGLISH. Under no circumstances generate Icelandic or any other non-English language.\nBREVITY & SPEED REQUIREMENT: Keep text dense, scannable, and concise. Each action step must be strictly 1-2 direct sentences without unnecessary introductory filler.\n\nCRITICAL GROUNDING & ANTI-HALLUCINATION RULES:\n1. HELPFUL FACTUAL GROUNDING: Incorporate factory specifications (LOTO isolators, part kit numbers, fastener torques, tolerances, page numbers) ONLY if they are explicitly present in the provided `=== OEM TECHNICAL SERVICE MANUAL ===` context.\n2. ABSOLUTELY NO HALLUCINATIONS OR GUESSING: If no OEM manual context is provided, or if a specific detail (like torque or page number) is not in the manual context, DO NOT invent or fabricate manual names, section numbers, or page numbers. Instead, provide clean standard industrial engineering steps without fabricated references.\n3. CITATION FORMAT: When referencing specifications from the provided OEM manual, append the exact citation from the source header (e.g. `[Ref: IPM XL-350 Hardware Manual, Sec 4.4.1, p. 88]`, `[Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44]`).\n\nFormat requirements:\n- \"ai_diagnostics\": Exactly 2-3 concise sentences stating the alarm condition, vibration/temperature values, RUL, and historical root cause.\n- \"action_plan\": EXACTLY 5 concise bullet points. Each bullet must start with a bolded header and use bolding for critical part codes, shelves, torques, and tolerances:\n  1. **LOTO & SAFETY**: Exact isolator switch, air dump valve, and mechanical locking pin [Ref: Manual Title, Section, Page if provided in manual context].\n  2. **SPARE PARTS**: Exact OEM kit number, component part number, and warehouse shelf location [Ref: Manual Title, Section, Page if provided in manual context].\n  3. **REMOVAL & REPLACEMENT**: Precision overhaul procedure, food-grade grease, and dial indicator inspection [Ref: Manual Title, Section, Page if provided in manual context].\n  4. **TORQUES & ALIGNMENT**: Exact bolt torque values (Nm in bold) and laser/dial tolerances [Ref: Manual Title, Section, Page if provided in manual context].\n  5. **STARTUP & VERIFICATION**: Run-in duration, baseline vibration RMS target (< 2.5 mm/s), and sign-off verification.\n\nReturn ONLY valid JSON (enclosed in ```json ... ``` or as plain JSON) with the exact keys:\n{\n  \"title\": \"[P1] Brim 1 (Main Grader Drive Motor) - Specific corrective action\",\n  \"ai_diagnostics\": \"2-3 crisp sentences in pure English.\",\n  \"action_plan\": [\n    \"1. **LOTO & SAFETY**: ...\",\n    \"2. **SPARE PARTS**: ...\",\n    \"3. **REMOVAL & REPLACEMENT**: ...\",\n    \"4. **TORQUES & ALIGNMENT**: ...\",\n    \"5. **STARTUP & VERIFICATION**: ...\"\n  ],\n  \"spare_part\": {\n    \"component\": \"Drive Motor Bearing\",\n    \"part_number\": \"Exact OEM part number or kit code\",\n    \"shelf_location\": \"Warehouse Shelf location (e.g. Shelf B-04)\",\n    \"quantity\": 1\n  },\n  \"safety_precautions\": \"1-2 sentence safety or LOTO warning.\"\n}\n", "PK": "TENANT#brim", "error": "", "epoch_ms": "1790846093417", "GSI1_PK": "ASSET#brim_1", "raw_response": "{\n  \"title\": \"[P1] Brim 1 (Main Grader Drive Motor) - Replace Drive Motor Bearing\",\n  \"ai_diagnostics\": \"Telemetry monitoring on Brim 1 (Main Grader Drive Motor) (Drive Motor Bearing) on sensor b0d9b54f3558 detected elevated degradation (Vibration RMS: 5.99 mm/s). Remaining Useful Life (RUL) projection indicates ~0.0 weeks to failure. Prioritized as P1 to prevent unscheduled plant downtime.\",\n  \"action_plan\": [\n    \"1. **LOTO & SAFETY**: Turn Main Infeed Conveyor Breaker Switch **4B** (Panel M1) to OFF, attach padlock, and verify 0V AC on motor terminals U1, V1, W1 [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].\",\n    \"2. **SPARE PARTS**: Retrieve Marel Infeed Drive Drum Bearing Kit **M-GRD-6205-KIT** (SKF 6205-2RSH + Splash Deflector M-DEF-25-SS) from warehouse **Shelf B-04** [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].\",\n    \"3. **REMOVAL & REPLACEMENT**: Disassemble infeed drum housing, inspect shaft runout (< 0.04 mm), seat splash disc with **1.0 mm** clearance, and apply Mobil SHC 627 food-grade grease [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].\",\n    \"4. **TORQUES & ALIGNMENT**: Torque motor foot bolts (M12) to **75 Nm**, end-caps (M8) to **24 Nm**, and belt tensioners to **35 Nm**. Verify radial alignment < 0.05 mm [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].\",\n    \"5. **STARTUP & VERIFICATION**: Remove LOTO, run empty for 10 minutes, and verify Treon vibration RMS drops below 2.5 mm/s on sensor b0d9b54f3558.\"\n  ]\n}", "SK": "LLMLOG#2026-10-01T09:14:53.417779+00:00#brim_1_e2c25a"}, {"GSI1_PK": "MACHINE#brim_1", "GSI1_SK": "METADATA", "PK": "TENANT#brim", "criticality": "BOTTLENECK", "department_id": "mottaka", "line_id": "mottokulina", "location": "Onshore Plant", "machine_id": "brim_1", "machine_name": "Brim 1 (Main Grader Drive Motor)", "plant_id": "nordurgardur", "qr_code": "QR-BRIM_1", "SK": "MACHINE#brim_1"}, {"GSI1_PK": "MACHINE#brim_2", "GSI1_SK": "METADATA", "PK": "TENANT#brim", "criticality": "IMPORTANT", "department_id": "mottaka", "line_id": "mottokulina", "location": "Onshore Plant", "machine_id": "brim_2", "machine_name": "Brim 2 (Filleting Conveyor Drive)", "plant_id": "nordurgardur", "qr_code": "QR-BRIM_2", "SK": "MACHINE#brim_2"}, {"PK": "TENANT#brim", "name": "Brim Processing Plant", "location": "Dalv\u00edk Onshore Processing Plant", "email": "info@brim.is", "SK": "METADATA"}, {"vibration_rms": "0", "timestamp": "2026-10-01T00:20:46.628121+00:00", "GSI1_SK": "METRIC#2026-10-01T00:20:46.628121+00:00", "vibration_peak": "0", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "42.5", "asset_id": "asset_01", "GSI1_PK": "SENSOR#4115563a", "SK": "METRIC#4115563a#2026-10-01T00:20:46.628121+00:00"}, {"unit": "V", "plant_id": "akureyri_plant", "component": "Drive Motor Bearing", "sensor_id": "4115563a", "timestamp": "2026-10-01T00:20:46.628121+00:00", "line_id": "line_filleting_01", "machine_id": "asset_01", "measurement_point": "battery_voltage", "expires_at": "1793406046", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T00:20:46.628121+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#4115563a", "SK": "METRIC#4115563a#2026-10-01T00:20:46.628121+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "akureyri_plant", "component": "Drive Motor Bearing", "sensor_id": "4115563a", "timestamp": "2026-10-01T00:20:46.628121+00:00", "line_id": "line_filleting_01", "machine_id": "asset_01", "measurement_point": "temperature", "expires_at": "1793406046", "value": "42.5", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T00:20:46.628121+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#4115563a", "SK": "METRIC#4115563a#2026-10-01T00:20:46.628121+00:00#temperature"}, {"unit": "mm/s", "plant_id": "akureyri_plant", "component": "Drive Motor Bearing", "sensor_id": "4115563a", "timestamp": "2026-10-01T00:20:46.628121+00:00", "line_id": "line_filleting_01", "machine_id": "asset_01", "expires_at": "1793406046", "measurement_point": "vibration_rms", "value": "0", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T00:20:46.628121+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#4115563a", "SK": "METRIC#4115563a#2026-10-01T00:20:46.628121+00:00#vibration_rms"}, {"vibration_rms": "1.4968872070312502", "timestamp": "2026-09-29T22:01:10.997000+00:00", "GSI1_SK": "METRIC#2026-09-29T22:01:10.997000+00:00", "battery_voltage": "3.6", "vibration_peak": "0", "PK": "TENANT#brim", "temperature": "12.718", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-29T22:01:10.997000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-29T22:01:10.997000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793316474", "measurement_point": "acceleration_rms", "value": "0.7137158203125", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-29T22:01:10.997000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-29T22:01:10.997000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-29T22:01:10.997000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793316474", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-29T22:01:10.997000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-29T22:01:10.997000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-29T22:01:10.997000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793316474", "measurement_point": "temperature", "value": "12.718", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-29T22:01:10.997000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-29T22:01:10.997000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-29T22:01:10.997000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793316474", "measurement_point": "vibration_rms", "value": "1.4968872070312502", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-29T22:01:10.997000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-29T22:01:10.997000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-29T22:01:10.997000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793316474", "measurement_point": "vibration_rms_x", "value": "1.6839981079101565", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-29T22:01:10.997000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-29T22:01:10.997000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-29T22:01:10.997000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793316474", "measurement_point": "vibration_rms_y", "value": "1.8711090087890625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-29T22:01:10.997000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-29T22:01:10.997000+00:00#vibration_rms_y"}, {"vibration_rms": "0.03742218017578125", "timestamp": "2026-09-30T02:01:05.201000+00:00", "GSI1_SK": "METRIC#2026-09-30T02:01:05.201000+00:00", "vibration_peak": "0.11226654052734375", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "10.671", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T02:01:05.201000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T02:01:05.201000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793325665", "measurement_point": "acceleration_rms", "value": "0.02155517578125", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T02:01:05.201000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T02:01:05.201000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T02:01:05.201000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793325665", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T02:01:05.201000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T02:01:05.201000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T02:01:05.201000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793325665", "measurement_point": "temperature", "value": "10.671", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T02:01:05.201000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T02:01:05.201000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T02:01:05.201000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793325665", "value": "0.11226654052734375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T02:01:05.201000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T02:01:05.201000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T02:01:05.201000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793325665", "measurement_point": "vibration_rms", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T02:01:05.201000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T02:01:05.201000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T02:01:05.201000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793325665", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T02:01:05.201000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T02:01:05.201000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T02:01:05.201000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793325665", "measurement_point": "vibration_rms_y", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T02:01:05.201000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T02:01:05.201000+00:00#vibration_rms_y"}, {"vibration_rms": "0.03742218017578125", "timestamp": "2026-09-30T05:00:58.047000+00:00", "GSI1_SK": "METRIC#2026-09-30T05:00:58.047000+00:00", "battery_voltage": "3.6", "vibration_peak": "0.11226654052734375", "PK": "TENANT#brim", "temperature": "10.367", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T05:00:58.047000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T05:00:58.047000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793336458", "measurement_point": "acceleration_rms", "value": "0.02155517578125", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T05:00:58.047000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T05:00:58.047000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T05:00:58.047000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793336458", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T05:00:58.047000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T05:00:58.047000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T05:00:58.047000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793336458", "measurement_point": "temperature", "value": "10.367", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T05:00:58.047000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T05:00:58.047000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T05:00:58.047000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793336458", "measurement_point": "vibration_peak", "value": "0.11226654052734375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T05:00:58.047000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T05:00:58.047000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T05:00:58.047000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793336458", "measurement_point": "vibration_rms", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T05:00:58.047000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T05:00:58.047000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T05:00:58.047000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793336458", "measurement_point": "vibration_rms_x", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T05:00:58.047000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T05:00:58.047000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T05:00:58.047000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793336458", "measurement_point": "vibration_rms_y", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T05:00:58.047000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T05:00:58.047000+00:00#vibration_rms_y"}, {"vibration_rms": "1.7214202880859377", "timestamp": "2026-09-30T07:54:57.383000+00:00", "GSI1_SK": "METRIC#2026-09-30T07:54:57.383000+00:00", "vibration_peak": "6.5114593505859375", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "9.632", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T07:54:57.383000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T07:54:57.383000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793346897", "measurement_point": "acceleration_rms", "value": "0.74964111328125", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T07:54:57.383000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T07:54:57.383000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T07:54:57.383000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793346897", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T07:54:57.383000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T07:54:57.383000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T07:54:57.383000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793346897", "measurement_point": "temperature", "value": "9.632", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T07:54:57.383000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T07:54:57.383000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T07:54:57.383000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793346897", "value": "6.5114593505859375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T07:54:57.383000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T07:54:57.383000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T07:54:57.383000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms", "expires_at": "1793346897", "value": "1.7214202880859377", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T07:54:57.383000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T07:54:57.383000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T07:54:57.383000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793346897", "value": "2.207908630371094", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T07:54:57.383000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T07:54:57.383000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T07:54:57.383000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793346897", "measurement_point": "vibration_rms_y", "value": "2.1704864501953125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T07:54:57.383000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T07:54:57.383000+00:00#vibration_rms_y"}, {"vibration_rms": "1.758842468261719", "timestamp": "2026-09-30T08:55:03.085000+00:00", "GSI1_SK": "METRIC#2026-09-30T08:55:03.085000+00:00", "battery_voltage": "3.6", "vibration_peak": "8.943901062011719", "PK": "TENANT#brim", "temperature": "8.085", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T08:55:03.085000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T08:55:03.085000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793350503", "measurement_point": "acceleration_rms", "value": "0.7280859375000001", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T08:55:03.085000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T08:55:03.085000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T08:55:03.085000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "battery_voltage", "expires_at": "1793350503", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T08:55:03.085000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T08:55:03.085000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T08:55:03.085000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793350503", "value": "8.085", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T08:55:03.085000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T08:55:03.085000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T08:55:03.085000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793350503", "value": "8.943901062011719", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T08:55:03.085000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T08:55:03.085000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T08:55:03.085000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793350503", "measurement_point": "vibration_rms", "value": "1.758842468261719", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T08:55:03.085000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T08:55:03.085000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T08:55:03.085000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793350503", "value": "3.4428405761718754", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T08:55:03.085000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T08:55:03.085000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T08:55:03.085000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793350503", "value": "3.2931518554687504", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T08:55:03.085000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T08:55:03.085000+00:00#vibration_rms_y"}, {"vibration_rms": "1.8711090087890625", "timestamp": "2026-09-30T09:54:57.973000+00:00", "GSI1_SK": "METRIC#2026-09-30T09:54:57.973000+00:00", "battery_voltage": "3.6", "vibration_peak": "9.355545043945312", "PK": "TENANT#brim", "temperature": "8.058", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T09:54:57.973000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T09:54:57.973000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793354098", "measurement_point": "acceleration_rms", "value": "0.7065307617187501", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T09:54:57.973000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T09:54:57.973000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T09:54:57.973000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793354098", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T09:54:57.973000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T09:54:57.973000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T09:54:57.973000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793354098", "measurement_point": "temperature", "value": "8.058", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T09:54:57.973000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T09:54:57.973000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T09:54:57.973000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793354098", "measurement_point": "vibration_peak", "value": "9.355545043945312", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T09:54:57.973000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T09:54:57.973000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T09:54:57.973000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793354098", "measurement_point": "vibration_rms", "value": "1.8711090087890625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T09:54:57.973000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T09:54:57.973000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T09:54:57.973000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793354098", "measurement_point": "vibration_rms_x", "value": "3.1434631347656254", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T09:54:57.973000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T09:54:57.973000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T09:54:57.973000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793354098", "measurement_point": "vibration_rms_y", "value": "3.0311965942382812", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T09:54:57.973000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T09:54:57.973000+00:00#vibration_rms_y"}, {"vibration_rms": "1.4968872070312502", "timestamp": "2026-09-30T10:55:13.391000+00:00", "GSI1_SK": "METRIC#2026-09-30T10:55:13.391000+00:00", "battery_voltage": "3.6", "vibration_peak": "7.634124755859375", "PK": "TENANT#brim", "temperature": "7.617", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T10:55:13.391000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T10:55:13.391000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793357713", "measurement_point": "acceleration_rms", "value": "0.61072998046875", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T10:55:13.391000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T10:55:13.391000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T10:55:13.391000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793357713", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T10:55:13.391000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T10:55:13.391000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T10:55:13.391000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793357713", "measurement_point": "temperature", "value": "7.617", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T10:55:13.391000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T10:55:13.391000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T10:55:13.391000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793357713", "measurement_point": "vibration_peak", "value": "7.634124755859375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T10:55:13.391000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T10:55:13.391000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T10:55:13.391000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793357713", "measurement_point": "vibration_rms", "value": "1.4968872070312502", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T10:55:13.391000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T10:55:13.391000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T10:55:13.391000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793357713", "measurement_point": "vibration_rms_x", "value": "2.8815078735351562", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T10:55:13.391000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T10:55:13.391000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T10:55:13.391000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793357713", "measurement_point": "vibration_rms_y", "value": "2.6195526123046875", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T10:55:13.391000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T10:55:13.391000+00:00#vibration_rms_y"}, {"vibration_rms": "1.2349319458007812", "timestamp": "2026-09-30T11:54:56.614000+00:00", "GSI1_SK": "METRIC#2026-09-30T11:54:56.614000+00:00", "vibration_peak": "11.63829803466797", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "8.578", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T11:54:56.614000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T11:54:56.614000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793361297", "value": "0.63228515625", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T11:54:56.614000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T11:54:56.614000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T11:54:56.614000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "battery_voltage", "expires_at": "1793361297", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T11:54:56.614000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T11:54:56.614000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T11:54:56.614000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793361297", "measurement_point": "temperature", "value": "8.578", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T11:54:56.614000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T11:54:56.614000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T11:54:56.614000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793361297", "value": "11.63829803466797", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T11:54:56.614000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T11:54:56.614000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T11:54:56.614000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793361297", "measurement_point": "vibration_rms", "value": "1.2349319458007812", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T11:54:56.614000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T11:54:56.614000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T11:54:56.614000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793361297", "value": "2.5821304321289062", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T11:54:56.614000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T11:54:56.614000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T11:54:56.614000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793361297", "measurement_point": "vibration_rms_y", "value": "2.1704864501953125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T11:54:56.614000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T11:54:56.614000+00:00#vibration_rms_y"}, {"vibration_rms": "1.5717315673828127", "timestamp": "2026-09-30T13:55:09.375000+00:00", "GSI1_SK": "METRIC#2026-09-30T13:55:09.375000+00:00", "battery_voltage": "3.6", "vibration_peak": "7.1102142333984375", "PK": "TENANT#brim", "temperature": "8.191", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T13:55:09.375000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T13:55:09.375000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793368509", "value": "0.689765625", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T13:55:09.375000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T13:55:09.375000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T13:55:09.375000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "battery_voltage", "expires_at": "1793368509", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T13:55:09.375000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T13:55:09.375000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T13:55:09.375000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793368509", "measurement_point": "temperature", "value": "8.191", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T13:55:09.375000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T13:55:09.375000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T13:55:09.375000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793368509", "measurement_point": "vibration_peak", "value": "7.1102142333984375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T13:55:09.375000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T13:55:09.375000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T13:55:09.375000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793368509", "measurement_point": "vibration_rms", "value": "1.5717315673828127", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T13:55:09.375000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T13:55:09.375000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T13:55:09.375000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793368509", "value": "1.9833755493164065", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T13:55:09.375000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T13:55:09.375000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T13:55:09.375000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793368509", "measurement_point": "vibration_rms_y", "value": "2.2827529907226567", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T13:55:09.375000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T13:55:09.375000+00:00#vibration_rms_y"}, {"vibration_rms": "1.459465026855469", "timestamp": "2026-09-30T14:55:04.909000+00:00", "GSI1_SK": "METRIC#2026-09-30T14:55:04.909000+00:00", "battery_voltage": "3.6", "vibration_peak": "30.910720825195312", "PK": "TENANT#brim", "temperature": "8.167", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T14:55:04.909000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T14:55:04.909000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793372106", "measurement_point": "acceleration_rms", "value": "0.7328759765625", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T14:55:04.909000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T14:55:04.909000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T14:55:04.909000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793372106", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T14:55:04.909000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T14:55:04.909000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T14:55:04.909000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793372106", "measurement_point": "temperature", "value": "8.167", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T14:55:04.909000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T14:55:04.909000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T14:55:04.909000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793372106", "value": "30.910720825195312", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T14:55:04.909000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T14:55:04.909000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T14:55:04.909000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms", "expires_at": "1793372106", "value": "1.459465026855469", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T14:55:04.909000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T14:55:04.909000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T14:55:04.909000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793372106", "value": "4.565505981445313", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T14:55:04.909000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T14:55:04.909000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T14:55:04.909000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793372106", "value": "1.7214202880859377", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T14:55:04.909000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T14:55:04.909000+00:00#vibration_rms_y"}, {"vibration_rms": "2.09564208984375", "timestamp": "2026-09-30T15:54:58.508000+00:00", "GSI1_SK": "METRIC#2026-09-30T15:54:58.508000+00:00", "battery_voltage": "3.6", "vibration_peak": "44.270439147949226", "PK": "TENANT#brim", "temperature": "9.015", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T15:54:58.508000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T15:54:58.508000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793375699", "value": "0.9340576171875", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T15:54:58.508000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T15:54:58.508000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T15:54:58.508000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "battery_voltage", "expires_at": "1793375699", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T15:54:58.508000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T15:54:58.508000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T15:54:58.508000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793375699", "value": "9.015", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T15:54:58.508000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T15:54:58.508000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T15:54:58.508000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793375699", "value": "44.270439147949226", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T15:54:58.508000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T15:54:58.508000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T15:54:58.508000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms", "expires_at": "1793375699", "value": "2.09564208984375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T15:54:58.508000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T15:54:58.508000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T15:54:58.508000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793375699", "value": "5.987548828125001", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T15:54:58.508000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T15:54:58.508000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T15:54:58.508000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793375699", "measurement_point": "vibration_rms_y", "value": "3.218307495117188", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T15:54:58.508000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T15:54:58.508000+00:00#vibration_rms_y"}, {"vibration_rms": "2.0207977294921875", "timestamp": "2026-09-30T16:55:02.392000+00:00", "GSI1_SK": "METRIC#2026-09-30T16:55:02.392000+00:00", "vibration_peak": "34.46582794189453", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "9.656", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T16:55:02.392000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T16:55:02.392000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793379302", "measurement_point": "acceleration_rms", "value": "1.02746337890625", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T16:55:02.392000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T16:55:02.392000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T16:55:02.392000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793379302", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T16:55:02.392000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T16:55:02.392000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T16:55:02.392000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793379302", "value": "9.656", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T16:55:02.392000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T16:55:02.392000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T16:55:02.392000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793379302", "measurement_point": "vibration_peak", "value": "34.46582794189453", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T16:55:02.392000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T16:55:02.392000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T16:55:02.392000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms", "expires_at": "1793379302", "value": "2.0207977294921875", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T16:55:02.392000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T16:55:02.392000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T16:55:02.392000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793379302", "measurement_point": "vibration_rms_x", "value": "5.9127044677734375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T16:55:02.392000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T16:55:02.392000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T16:55:02.392000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793379302", "measurement_point": "vibration_rms_y", "value": "2.918930053710938", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T16:55:02.392000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T16:55:02.392000+00:00#vibration_rms_y"}, {"vibration_rms": "2.09564208984375", "timestamp": "2026-09-30T17:54:56.280000+00:00", "GSI1_SK": "METRIC#2026-09-30T17:54:56.280000+00:00", "vibration_peak": "36.52404785156251", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "9.792", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T17:54:56.280000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T17:54:56.280000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793382897", "value": "1.36276611328125", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T17:54:56.280000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T17:54:56.280000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T17:54:56.280000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793382897", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T17:54:56.280000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T17:54:56.280000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T17:54:56.280000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793382897", "measurement_point": "temperature", "value": "9.792", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T17:54:56.280000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T17:54:56.280000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T17:54:56.280000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793382897", "value": "36.52404785156251", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T17:54:56.280000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T17:54:56.280000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T17:54:56.280000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms", "expires_at": "1793382897", "value": "2.09564208984375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T17:54:56.280000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T17:54:56.280000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T17:54:56.280000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793382897", "value": "5.239105224609375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T17:54:56.280000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T17:54:56.280000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T17:54:56.280000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793382897", "measurement_point": "vibration_rms_y", "value": "2.6569747924804688", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T17:54:56.280000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T17:54:56.280000+00:00#vibration_rms_y"}, {"vibration_rms": "1.9085311889648438", "timestamp": "2026-09-30T18:55:00.594000+00:00", "GSI1_SK": "METRIC#2026-09-30T18:55:00.594000+00:00", "battery_voltage": "3.6", "vibration_peak": "26.532325744628906", "PK": "TENANT#brim", "temperature": "12.414", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T18:55:00.594000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T18:55:00.594000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793386502", "value": "0.8669970703125001", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T18:55:00.594000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T18:55:00.594000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T18:55:00.594000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793386502", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T18:55:00.594000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T18:55:00.594000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T18:55:00.594000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793386502", "value": "12.414", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T18:55:00.594000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T18:55:00.594000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T18:55:00.594000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793386502", "measurement_point": "vibration_peak", "value": "26.532325744628906", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T18:55:00.594000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T18:55:00.594000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T18:55:00.594000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793386502", "measurement_point": "vibration_rms", "value": "1.9085311889648438", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T18:55:00.594000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T18:55:00.594000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T18:55:00.594000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793386502", "value": "6.3617706298828125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T18:55:00.594000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T18:55:00.594000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T18:55:00.594000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793386502", "value": "2.207908630371094", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T18:55:00.594000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T18:55:00.594000+00:00#vibration_rms_y"}, {"vibration_rms": "0.0748443603515625", "timestamp": "2026-09-30T19:55:55.307000+00:00", "GSI1_SK": "METRIC#2026-09-30T19:55:55.307000+00:00", "battery_voltage": "3.6", "vibration_peak": "0.4116439819335938", "PK": "TENANT#brim", "temperature": "12.476", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T19:55:55.307000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T19:55:55.307000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793390156", "value": "0.03113525390625", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T19:55:55.307000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T19:55:55.307000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T19:55:55.307000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "battery_voltage", "expires_at": "1793390156", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T19:55:55.307000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T19:55:55.307000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T19:55:55.307000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793390156", "value": "12.476", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T19:55:55.307000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T19:55:55.307000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T19:55:55.307000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793390156", "value": "0.4116439819335938", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T19:55:55.307000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T19:55:55.307000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T19:55:55.307000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793390156", "measurement_point": "vibration_rms", "value": "0.0748443603515625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T19:55:55.307000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T19:55:55.307000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T19:55:55.307000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793390156", "value": "0.11226654052734375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T19:55:55.307000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T19:55:55.307000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T19:55:55.307000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793390156", "value": "0.149688720703125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T19:55:55.307000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T19:55:55.307000+00:00#vibration_rms_y"}, {"vibration_rms": "1.0103988647460938", "timestamp": "2026-09-30T20:55:48.890000+00:00", "GSI1_SK": "METRIC#2026-09-30T20:55:48.890000+00:00", "vibration_peak": "15.642471313476562", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "12.289", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T20:55:48.890000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T20:55:48.890000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793393749", "value": "0.689765625", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T20:55:48.890000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T20:55:48.890000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T20:55:48.890000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "battery_voltage", "expires_at": "1793393749", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T20:55:48.890000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T20:55:48.890000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T20:55:48.890000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793393749", "value": "12.289", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T20:55:48.890000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T20:55:48.890000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T20:55:48.890000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793393749", "value": "15.642471313476562", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T20:55:48.890000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T20:55:48.890000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T20:55:48.890000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms", "expires_at": "1793393749", "value": "1.0103988647460938", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T20:55:48.890000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T20:55:48.890000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T20:55:48.890000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793393749", "value": "4.266128540039063", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T20:55:48.890000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T20:55:48.890000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T20:55:48.890000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793393749", "measurement_point": "vibration_rms_y", "value": "4.378395080566406", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T20:55:48.890000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T20:55:48.890000+00:00#vibration_rms_y"}, {"vibration_rms": "1.047821044921875", "timestamp": "2026-09-30T21:55:53.285000+00:00", "GSI1_SK": "METRIC#2026-09-30T21:55:53.285000+00:00", "vibration_peak": "13.022918701171875", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "11.617", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T21:55:53.285000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T21:55:53.285000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793397353", "value": "0.5700146484375", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T21:55:53.285000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T21:55:53.285000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T21:55:53.285000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793397353", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T21:55:53.285000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T21:55:53.285000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T21:55:53.285000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793397353", "measurement_point": "temperature", "value": "11.617", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T21:55:53.285000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T21:55:53.285000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T21:55:53.285000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793397353", "value": "13.022918701171875", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T21:55:53.285000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T21:55:53.285000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T21:55:53.285000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793397353", "measurement_point": "vibration_rms", "value": "1.047821044921875", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T21:55:53.285000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T21:55:53.285000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T21:55:53.285000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793397353", "measurement_point": "vibration_rms_x", "value": "3.4054183959960938", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T21:55:53.285000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T21:55:53.285000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T21:55:53.285000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793397353", "value": "2.9937744140625004", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T21:55:53.285000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T21:55:53.285000+00:00#vibration_rms_y"}, {"vibration_rms": "1.8336868286132812", "timestamp": "2026-09-30T22:55:57.804000+00:00", "GSI1_SK": "METRIC#2026-09-30T22:55:57.804000+00:00", "battery_voltage": "3.6", "vibration_peak": "20.582199096679688", "PK": "TENANT#brim", "temperature": "12.96", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T22:55:57.804000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T22:55:57.804000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793400958", "value": "0.8238867187500001", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T22:55:57.804000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T22:55:57.804000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T22:55:57.804000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "battery_voltage", "expires_at": "1793400958", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T22:55:57.804000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T22:55:57.804000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T22:55:57.804000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793400958", "value": "12.96", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T22:55:57.804000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T22:55:57.804000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T22:55:57.804000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793400958", "measurement_point": "vibration_peak", "value": "20.582199096679688", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T22:55:57.804000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T22:55:57.804000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T22:55:57.804000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793400958", "measurement_point": "vibration_rms", "value": "1.8336868286132812", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T22:55:57.804000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T22:55:57.804000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T22:55:57.804000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793400958", "value": "3.6673736572265625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T22:55:57.804000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T22:55:57.804000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-09-30T22:55:57.804000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793400958", "value": "4.715194702148438", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T22:55:57.804000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-09-30T22:55:57.804000+00:00#vibration_rms_y"}, {"vibration_rms": "0.03742218017578125", "timestamp": "2026-10-01T01:55:45.069000+00:00", "GSI1_SK": "METRIC#2026-10-01T01:55:45.069000+00:00", "vibration_peak": "0.0748443603515625", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "10.519", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T01:55:45.069000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T01:55:45.069000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793411745", "value": "0.02155517578125", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T01:55:45.069000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T01:55:45.069000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T01:55:45.069000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "battery_voltage", "expires_at": "1793411745", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T01:55:45.069000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T01:55:45.069000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T01:55:45.069000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793411745", "value": "10.519", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T01:55:45.069000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T01:55:45.069000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T01:55:45.069000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793411745", "value": "0.0748443603515625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T01:55:45.069000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T01:55:45.069000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T01:55:45.069000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms", "expires_at": "1793411745", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T01:55:45.069000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T01:55:45.069000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T01:55:45.069000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793411745", "measurement_point": "vibration_rms_x", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T01:55:45.069000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T01:55:45.069000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T01:55:45.069000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793411745", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T01:55:45.069000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T01:55:45.069000+00:00#vibration_rms_y"}, {"vibration_rms": "0.03742218017578125", "timestamp": "2026-10-01T04:55:43.778000+00:00", "GSI1_SK": "METRIC#2026-10-01T04:55:43.778000+00:00", "battery_voltage": "3.6", "vibration_peak": "0.11226654052734375", "PK": "TENANT#brim", "temperature": "10.171", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T04:55:43.778000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T04:55:43.778000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793422543", "measurement_point": "acceleration_rms", "value": "0.02155517578125", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T04:55:43.778000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T04:55:43.778000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T04:55:43.778000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793422543", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T04:55:43.778000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T04:55:43.778000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T04:55:43.778000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793422543", "value": "10.171", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T04:55:43.778000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T04:55:43.778000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T04:55:43.778000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793422543", "measurement_point": "vibration_peak", "value": "0.11226654052734375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T04:55:43.778000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T04:55:43.778000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T04:55:43.778000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793422543", "measurement_point": "vibration_rms", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T04:55:43.778000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T04:55:43.778000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T04:55:43.778000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793422543", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T04:55:43.778000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T04:55:43.778000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T04:55:43.778000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793422543", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T04:55:43.778000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T04:55:43.778000+00:00#vibration_rms_y"}, {"vibration_rms": "0.03742218017578125", "timestamp": "2026-10-01T06:04:49.604000+00:00", "GSI1_SK": "METRIC#2026-10-01T06:04:49.604000+00:00", "battery_voltage": "3.6", "vibration_peak": "0.26195526123046875", "PK": "TENANT#brim", "temperature": "10.312", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T06:04:49.604000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T06:04:49.604000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793426691", "value": "0.02155517578125", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T06:04:49.604000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T06:04:49.604000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T06:04:49.604000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793426691", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T06:04:49.604000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T06:04:49.604000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T06:04:49.604000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793426691", "value": "10.312", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T06:04:49.604000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T06:04:49.604000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T06:04:49.604000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793426691", "measurement_point": "vibration_peak", "value": "0.26195526123046875", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T06:04:49.604000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T06:04:49.604000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T06:04:49.604000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793426691", "measurement_point": "vibration_rms", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T06:04:49.604000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T06:04:49.604000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T06:04:49.604000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793426691", "value": "0.149688720703125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T06:04:49.604000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T06:04:49.604000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T06:04:49.604000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793426691", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T06:04:49.604000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T06:04:49.604000+00:00#vibration_rms_y"}, {"vibration_rms": "0.9355545043945312", "timestamp": "2026-10-01T07:04:53.524000+00:00", "GSI1_SK": "METRIC#2026-10-01T07:04:53.524000+00:00", "vibration_peak": "13.846206665039064", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "10.921", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T07:04:53.524000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T07:04:53.524000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793430294", "measurement_point": "acceleration_rms", "value": "0.8574169921875", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T07:04:53.524000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T07:04:53.524000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T07:04:53.524000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "battery_voltage", "expires_at": "1793430294", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T07:04:53.524000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T07:04:53.524000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T07:04:53.524000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793430294", "value": "10.921", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T07:04:53.524000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T07:04:53.524000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T07:04:53.524000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793430294", "value": "13.846206665039064", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T07:04:53.524000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T07:04:53.524000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T07:04:53.524000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793430294", "measurement_point": "vibration_rms", "value": "0.9355545043945312", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T07:04:53.524000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T07:04:53.524000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T07:04:53.524000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793430294", "measurement_point": "vibration_rms_x", "value": "3.742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T07:04:53.524000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T07:04:53.524000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T07:04:53.524000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793430294", "value": "4.640350341796875", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T07:04:53.524000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T07:04:53.524000+00:00#vibration_rms_y"}, {"vibration_rms": "0.7484436035156251", "timestamp": "2026-10-01T08:04:55.936000+00:00", "GSI1_SK": "METRIC#2026-10-01T08:04:55.936000+00:00", "battery_voltage": "3.6", "vibration_peak": "10.1788330078125", "PK": "TENANT#brim", "temperature": "9.429", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T08:04:55.936000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T08:04:55.936000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793433896", "measurement_point": "acceleration_rms", "value": "0.67060546875", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T08:04:55.936000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T08:04:55.936000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T08:04:55.936000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793433896", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T08:04:55.936000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T08:04:55.936000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T08:04:55.936000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793433896", "value": "9.429", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T08:04:55.936000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T08:04:55.936000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T08:04:55.936000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793433896", "measurement_point": "vibration_peak", "value": "10.1788330078125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T08:04:55.936000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T08:04:55.936000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T08:04:55.936000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793433896", "measurement_point": "vibration_rms", "value": "0.7484436035156251", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T08:04:55.936000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T08:04:55.936000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T08:04:55.936000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793433896", "measurement_point": "vibration_rms_x", "value": "2.544708251953125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T08:04:55.936000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T08:04:55.936000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T08:04:55.936000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793433896", "value": "2.0207977294921875", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T08:04:55.936000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T08:04:55.936000+00:00#vibration_rms_y"}, {"vibration_rms": "0.6735992431640625", "timestamp": "2026-10-01T09:04:51.382000+00:00", "GSI1_SK": "METRIC#2026-10-01T09:04:51.382000+00:00", "vibration_peak": "3.1060409545898438", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "8.367", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T09:04:51.382000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T09:04:51.382000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793437491", "value": "0.62989013671875", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T09:04:51.382000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T09:04:51.382000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T09:04:51.382000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "battery_voltage", "expires_at": "1793437491", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T09:04:51.382000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T09:04:51.382000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T09:04:51.382000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793437491", "value": "8.367", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T09:04:51.382000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T09:04:51.382000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T09:04:51.382000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793437491", "measurement_point": "vibration_peak", "value": "3.1060409545898438", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T09:04:51.382000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T09:04:51.382000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T09:04:51.382000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms", "expires_at": "1793437491", "value": "0.6735992431640625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T09:04:51.382000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T09:04:51.382000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T09:04:51.382000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793437491", "measurement_point": "vibration_rms_x", "value": "1.1226654052734375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T09:04:51.382000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T09:04:51.382000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T09:04:51.382000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793437491", "measurement_point": "vibration_rms_y", "value": "1.2349319458007812", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T09:04:51.382000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T09:04:51.382000+00:00#vibration_rms_y"}, {"vibration_rms": "0.89813232421875", "timestamp": "2026-10-01T11:04:57.106000+00:00", "GSI1_SK": "METRIC#2026-10-01T11:04:57.106000+00:00", "vibration_peak": "4.565505981445313", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "7.57", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T11:04:57.106000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T11:04:57.106000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793444698", "value": "0.57240966796875", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T11:04:57.106000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T11:04:57.106000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T11:04:57.106000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793444698", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T11:04:57.106000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T11:04:57.106000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T11:04:57.106000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793444698", "measurement_point": "temperature", "value": "7.57", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T11:04:57.106000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T11:04:57.106000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T11:04:57.106000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793444698", "value": "4.565505981445313", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T11:04:57.106000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T11:04:57.106000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T11:04:57.106000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793444698", "measurement_point": "vibration_rms", "value": "0.89813232421875", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T11:04:57.106000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T11:04:57.106000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T11:04:57.106000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793444698", "value": "1.609153747558594", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T11:04:57.106000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T11:04:57.106000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T11:04:57.106000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793444698", "measurement_point": "vibration_rms_y", "value": "1.5343093872070315", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T11:04:57.106000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T11:04:57.106000+00:00#vibration_rms_y"}, {"vibration_rms": "0.89813232421875", "timestamp": "2026-10-01T12:05:01.329000+00:00", "GSI1_SK": "METRIC#2026-10-01T12:05:01.329000+00:00", "battery_voltage": "3.6", "vibration_peak": "29.151878356933597", "PK": "TENANT#brim", "temperature": "8.027", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T12:05:01.329000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T12:05:01.329000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793448301", "measurement_point": "acceleration_rms", "value": "0.7280859375000001", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T12:05:01.329000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T12:05:01.329000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T12:05:01.329000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793448301", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T12:05:01.329000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T12:05:01.329000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T12:05:01.329000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793448301", "measurement_point": "temperature", "value": "8.027", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T12:05:01.329000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T12:05:01.329000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T12:05:01.329000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793448301", "value": "29.151878356933597", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T12:05:01.329000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T12:05:01.329000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T12:05:01.329000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793448301", "measurement_point": "vibration_rms", "value": "0.89813232421875", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T12:05:01.329000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T12:05:01.329000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T12:05:01.329000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793448301", "measurement_point": "vibration_rms_x", "value": "5.201683044433595", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T12:05:01.329000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T12:05:01.329000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T12:05:01.329000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793448301", "measurement_point": "vibration_rms_y", "value": "2.058219909667969", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T12:05:01.329000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T12:05:01.329000+00:00#vibration_rms_y"}, {"vibration_rms": "0.6735992431640625", "timestamp": "2026-10-01T13:05:16.151000+00:00", "GSI1_SK": "METRIC#2026-10-01T13:05:16.151000+00:00", "vibration_peak": "4.528083801269531", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "7.585", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T13:05:16.151000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T13:05:16.151000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793451916", "measurement_point": "acceleration_rms", "value": "0.57240966796875", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T13:05:16.151000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T13:05:16.151000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T13:05:16.151000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793451916", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T13:05:16.151000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T13:05:16.151000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T13:05:16.151000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793451916", "value": "7.585", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T13:05:16.151000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T13:05:16.151000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T13:05:16.151000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793451916", "value": "4.528083801269531", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T13:05:16.151000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T13:05:16.151000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T13:05:16.151000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793451916", "measurement_point": "vibration_rms", "value": "0.6735992431640625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T13:05:16.151000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T13:05:16.151000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T13:05:16.151000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793451916", "measurement_point": "vibration_rms_x", "value": "1.2723541259765625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T13:05:16.151000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T13:05:16.151000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T13:05:16.151000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793451916", "value": "1.4968872070312502", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T13:05:16.151000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T13:05:16.151000+00:00#vibration_rms_y"}, {"vibration_rms": "0.6735992431640625", "timestamp": "2026-10-01T14:05:02.226000+00:00", "GSI1_SK": "METRIC#2026-10-01T14:05:02.226000+00:00", "battery_voltage": "3.6", "vibration_peak": "4.303550720214844", "PK": "TENANT#brim", "temperature": "7.578", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T14:05:02.226000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T14:05:02.226000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793455502", "measurement_point": "acceleration_rms", "value": "0.6059399414062501", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T14:05:02.226000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T14:05:02.226000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T14:05:02.226000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793455502", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T14:05:02.226000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T14:05:02.226000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T14:05:02.226000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793455502", "measurement_point": "temperature", "value": "7.578", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T14:05:02.226000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T14:05:02.226000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T14:05:02.226000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793455502", "value": "4.303550720214844", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T14:05:02.226000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T14:05:02.226000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T14:05:02.226000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms", "expires_at": "1793455502", "value": "0.6735992431640625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T14:05:02.226000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T14:05:02.226000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T14:05:02.226000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_x", "expires_at": "1793455502", "value": "1.1600875854492188", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T14:05:02.226000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T14:05:02.226000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T14:05:02.226000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793455502", "measurement_point": "vibration_rms_y", "value": "1.3097763061523438", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T14:05:02.226000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T14:05:02.226000+00:00#vibration_rms_y"}, {"vibration_rms": "0.5613327026367188", "timestamp": "2026-10-01T15:04:57.599000+00:00", "GSI1_SK": "METRIC#2026-10-01T15:04:57.599000+00:00", "vibration_peak": "3.1808853149414062", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "7.675", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T15:04:57.599000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T15:04:57.599000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "acceleration_rms", "expires_at": "1793459097", "value": "0.5316943359375", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T15:04:57.599000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T15:04:57.599000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T15:04:57.599000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793459097", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T15:04:57.599000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T15:04:57.599000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T15:04:57.599000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "temperature", "expires_at": "1793459097", "value": "7.675", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T15:04:57.599000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T15:04:57.599000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T15:04:57.599000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_peak", "expires_at": "1793459097", "value": "3.1808853149414062", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T15:04:57.599000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T15:04:57.599000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T15:04:57.599000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793459097", "measurement_point": "vibration_rms", "value": "0.5613327026367188", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T15:04:57.599000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T15:04:57.599000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T15:04:57.599000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "expires_at": "1793459097", "measurement_point": "vibration_rms_x", "value": "1.1600875854492188", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T15:04:57.599000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T15:04:57.599000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Conveyor Roller Bearing", "sensor_id": "8edbe59e5e78", "timestamp": "2026-10-01T15:04:57.599000+00:00", "line_id": "mottokulina", "machine_id": "brim_2", "measurement_point": "vibration_rms_y", "expires_at": "1793459097", "value": "1.347198486328125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T15:04:57.599000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "METRIC#8edbe59e5e78#2026-10-01T15:04:57.599000+00:00#vibration_rms_y"}, {"vibration_rms": "1.347198486328125", "timestamp": "2026-09-29T22:13:38.531000+00:00", "GSI1_SK": "METRIC#2026-09-29T22:13:38.531000+00:00", "battery_voltage": "3.6", "vibration_peak": "0", "PK": "TENANT#brim", "temperature": "18.992", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-29T22:13:38.531000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-29T22:13:38.531000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793316474", "measurement_point": "acceleration_rms", "value": "0.737666015625", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-29T22:13:38.531000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-29T22:13:38.531000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-29T22:13:38.531000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793316474", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-29T22:13:38.531000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-29T22:13:38.531000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-29T22:13:38.531000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793316474", "measurement_point": "temperature", "value": "18.992", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-29T22:13:38.531000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-29T22:13:38.531000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-29T22:13:38.531000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793316474", "measurement_point": "vibration_rms", "value": "1.347198486328125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-29T22:13:38.531000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-29T22:13:38.531000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-29T22:13:38.531000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793316474", "measurement_point": "vibration_rms_x", "value": "1.1600875854492188", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-29T22:13:38.531000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-29T22:13:38.531000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-29T22:13:38.531000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793316474", "measurement_point": "vibration_rms_y", "value": "1.7962646484375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-29T22:13:38.531000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-29T22:13:38.531000+00:00#vibration_rms_y"}, {"vibration_rms": "0.03742218017578125", "timestamp": "2026-09-30T02:12:22.583000+00:00", "GSI1_SK": "METRIC#2026-09-30T02:12:22.583000+00:00", "battery_voltage": "3.6", "vibration_peak": "0.0748443603515625", "PK": "TENANT#brim", "temperature": "15.945", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T02:12:22.583000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T02:12:22.583000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793326342", "measurement_point": "acceleration_rms", "value": "0.01916015625", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T02:12:22.583000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T02:12:22.583000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T02:12:22.583000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "battery_voltage", "expires_at": "1793326342", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T02:12:22.583000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T02:12:22.583000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T02:12:22.583000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793326342", "measurement_point": "temperature", "value": "15.945", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T02:12:22.583000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T02:12:22.583000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T02:12:22.583000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793326342", "measurement_point": "vibration_peak", "value": "0.0748443603515625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T02:12:22.583000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T02:12:22.583000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T02:12:22.583000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms", "expires_at": "1793326342", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T02:12:22.583000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T02:12:22.583000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T02:12:22.583000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793326342", "measurement_point": "vibration_rms_x", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T02:12:22.583000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T02:12:22.583000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T02:12:22.583000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793326342", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T02:12:22.583000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T02:12:22.583000+00:00#vibration_rms_y"}, {"vibration_rms": "0.03742218017578125", "timestamp": "2026-09-30T05:11:33.166000+00:00", "GSI1_SK": "METRIC#2026-09-30T05:11:33.166000+00:00", "battery_voltage": "3.6", "vibration_peak": "0.11226654052734375", "PK": "TENANT#brim", "temperature": "14.488", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T05:11:33.166000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T05:11:33.166000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793337093", "measurement_point": "acceleration_rms", "value": "0.02155517578125", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T05:11:33.166000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T05:11:33.166000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T05:11:33.166000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793337093", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T05:11:33.166000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T05:11:33.166000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T05:11:33.166000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793337093", "measurement_point": "temperature", "value": "14.488", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T05:11:33.166000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T05:11:33.166000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T05:11:33.166000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793337093", "measurement_point": "vibration_peak", "value": "0.11226654052734375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T05:11:33.166000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T05:11:33.166000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T05:11:33.166000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793337093", "measurement_point": "vibration_rms", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T05:11:33.166000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T05:11:33.166000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T05:11:33.166000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793337093", "measurement_point": "vibration_rms_x", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T05:11:33.166000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T05:11:33.166000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T05:11:33.166000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793337093", "measurement_point": "vibration_rms_y", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T05:11:33.166000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T05:11:33.166000+00:00#vibration_rms_y"}, {"vibration_rms": "2.3201751708984375", "timestamp": "2026-09-30T08:54:44.119000+00:00", "GSI1_SK": "METRIC#2026-09-30T08:54:44.119000+00:00", "vibration_peak": "5.1642608642578125", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "11.785", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T08:54:44.119000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T08:54:44.119000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793350484", "measurement_point": "acceleration_rms", "value": "0.7616162109375001", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T08:54:44.119000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T08:54:44.119000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T08:54:44.119000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "battery_voltage", "expires_at": "1793350484", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T08:54:44.119000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T08:54:44.119000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T08:54:44.119000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793350484", "measurement_point": "temperature", "value": "11.785", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T08:54:44.119000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T08:54:44.119000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T08:54:44.119000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793350484", "measurement_point": "vibration_peak", "value": "5.1642608642578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T08:54:44.119000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T08:54:44.119000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T08:54:44.119000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793350484", "measurement_point": "vibration_rms", "value": "2.3201751708984375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T08:54:44.119000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T08:54:44.119000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T08:54:44.119000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793350484", "measurement_point": "vibration_rms_x", "value": "1.8336868286132812", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T08:54:44.119000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T08:54:44.119000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T08:54:44.119000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793350484", "value": "2.39501953125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T08:54:44.119000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T08:54:44.119000+00:00#vibration_rms_y"}, {"vibration_rms": "1.2723541259765625", "timestamp": "2026-09-30T09:54:19.015000+00:00", "GSI1_SK": "METRIC#2026-09-30T09:54:19.015000+00:00", "battery_voltage": "3.6", "vibration_peak": "4.7900390625", "PK": "TENANT#brim", "temperature": "10.859", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T09:54:19.015000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T09:54:19.015000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793354060", "measurement_point": "acceleration_rms", "value": "0.70174072265625", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T09:54:19.015000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T09:54:19.015000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T09:54:19.015000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793354060", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T09:54:19.015000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T09:54:19.015000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T09:54:19.015000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793354060", "measurement_point": "temperature", "value": "10.859", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T09:54:19.015000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T09:54:19.015000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T09:54:19.015000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793354060", "measurement_point": "vibration_peak", "value": "4.7900390625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T09:54:19.015000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T09:54:19.015000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T09:54:19.015000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793354060", "measurement_point": "vibration_rms", "value": "1.2723541259765625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T09:54:19.015000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T09:54:19.015000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T09:54:19.015000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793354060", "measurement_point": "vibration_rms_x", "value": "1.5717315673828127", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T09:54:19.015000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T09:54:19.015000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T09:54:19.015000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793354060", "measurement_point": "vibration_rms_y", "value": "2.357597351074219", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T09:54:19.015000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T09:54:19.015000+00:00#vibration_rms_y"}, {"vibration_rms": "1.9085311889648438", "timestamp": "2026-09-30T12:53:33.477000+00:00", "GSI1_SK": "METRIC#2026-09-30T12:53:33.477000+00:00", "battery_voltage": "3.6", "vibration_peak": "9.392967224121094", "PK": "TENANT#brim", "temperature": "12.746", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T12:53:33.477000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T12:53:33.477000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793364814", "measurement_point": "acceleration_rms", "value": "0.833466796875", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T12:53:33.477000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T12:53:33.477000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T12:53:33.477000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793364814", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T12:53:33.477000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T12:53:33.477000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T12:53:33.477000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793364814", "measurement_point": "temperature", "value": "12.746", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T12:53:33.477000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T12:53:33.477000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T12:53:33.477000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_peak", "expires_at": "1793364814", "value": "9.392967224121094", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T12:53:33.477000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T12:53:33.477000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T12:53:33.477000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793364814", "measurement_point": "vibration_rms", "value": "1.9085311889648438", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T12:53:33.477000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T12:53:33.477000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T12:53:33.477000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_x", "expires_at": "1793364814", "value": "3.9293289184570312", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T12:53:33.477000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T12:53:33.477000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T12:53:33.477000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793364814", "value": "4.116439819335938", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T12:53:33.477000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T12:53:33.477000+00:00#vibration_rms_y"}, {"vibration_rms": "3.7047958374023438", "timestamp": "2026-09-30T13:53:10.202000+00:00", "GSI1_SK": "METRIC#2026-09-30T13:53:10.202000+00:00", "battery_voltage": "3.6", "vibration_peak": "11.63829803466797", "PK": "TENANT#brim", "temperature": "13.41", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T13:53:10.202000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T13:53:10.202000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793368390", "measurement_point": "acceleration_rms", "value": "0.8837622070312501", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T13:53:10.202000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T13:53:10.202000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T13:53:10.202000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "battery_voltage", "expires_at": "1793368390", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T13:53:10.202000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T13:53:10.202000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T13:53:10.202000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793368390", "measurement_point": "temperature", "value": "13.41", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T13:53:10.202000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T13:53:10.202000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T13:53:10.202000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_peak", "expires_at": "1793368390", "value": "11.63829803466797", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T13:53:10.202000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T13:53:10.202000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T13:53:10.202000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793368390", "measurement_point": "vibration_rms", "value": "3.7047958374023438", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T13:53:10.202000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T13:53:10.202000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T13:53:10.202000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_x", "expires_at": "1793368390", "value": "4.266128540039063", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T13:53:10.202000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T13:53:10.202000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T13:53:10.202000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793368390", "value": "4.004173278808594", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T13:53:10.202000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T13:53:10.202000+00:00#vibration_rms_y"}, {"vibration_rms": "1.7962646484375", "timestamp": "2026-09-30T15:52:38.952000+00:00", "GSI1_SK": "METRIC#2026-09-30T15:52:38.952000+00:00", "vibration_peak": "4.116439819335938", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "13.304", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T15:52:38.952000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T15:52:38.952000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793375560", "measurement_point": "acceleration_rms", "value": "0.795146484375", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T15:52:38.952000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T15:52:38.952000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T15:52:38.952000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "battery_voltage", "expires_at": "1793375560", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T15:52:38.952000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T15:52:38.952000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T15:52:38.952000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "temperature", "expires_at": "1793375560", "value": "13.304", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T15:52:38.952000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T15:52:38.952000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T15:52:38.952000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_peak", "expires_at": "1793375560", "value": "4.116439819335938", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T15:52:38.952000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T15:52:38.952000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T15:52:38.952000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793375560", "measurement_point": "vibration_rms", "value": "1.7962646484375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T15:52:38.952000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T15:52:38.952000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T15:52:38.952000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_x", "expires_at": "1793375560", "value": "1.3097763061523438", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T15:52:38.952000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T15:52:38.952000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T15:52:38.952000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793375560", "measurement_point": "vibration_rms_y", "value": "1.4220428466796877", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T15:52:38.952000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T15:52:38.952000+00:00#vibration_rms_y"}, {"vibration_rms": "1.945953369140625", "timestamp": "2026-09-30T16:52:23.070000+00:00", "GSI1_SK": "METRIC#2026-09-30T16:52:23.070000+00:00", "vibration_peak": "4.415817260742188", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "14.906", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T16:52:23.070000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T16:52:23.070000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793379144", "measurement_point": "acceleration_rms", "value": "0.7879614257812501", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T16:52:23.070000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T16:52:23.070000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T16:52:23.070000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "battery_voltage", "expires_at": "1793379144", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T16:52:23.070000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T16:52:23.070000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T16:52:23.070000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "temperature", "expires_at": "1793379144", "value": "14.906", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T16:52:23.070000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T16:52:23.070000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T16:52:23.070000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793379144", "measurement_point": "vibration_peak", "value": "4.415817260742188", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T16:52:23.070000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T16:52:23.070000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T16:52:23.070000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms", "expires_at": "1793379144", "value": "1.945953369140625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T16:52:23.070000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T16:52:23.070000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T16:52:23.070000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_x", "expires_at": "1793379144", "value": "1.0852432250976562", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T16:52:23.070000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T16:52:23.070000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T16:52:23.070000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793379144", "value": "2.058219909667969", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T16:52:23.070000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T16:52:23.070000+00:00#vibration_rms_y"}, {"vibration_rms": "1.945953369140625", "timestamp": "2026-09-30T17:52:06.851000+00:00", "GSI1_SK": "METRIC#2026-09-30T17:52:06.851000+00:00", "vibration_peak": "4.977149963378906", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "15.351", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T17:52:06.851000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T17:52:06.851000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793382728", "measurement_point": "acceleration_rms", "value": "0.7616162109375001", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T17:52:06.851000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T17:52:06.851000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T17:52:06.851000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793382728", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T17:52:06.851000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T17:52:06.851000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T17:52:06.851000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "temperature", "expires_at": "1793382728", "value": "15.351", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T17:52:06.851000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T17:52:06.851000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T17:52:06.851000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_peak", "expires_at": "1793382728", "value": "4.977149963378906", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T17:52:06.851000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T17:52:06.851000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T17:52:06.851000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms", "expires_at": "1793382728", "value": "1.945953369140625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T17:52:06.851000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T17:52:06.851000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T17:52:06.851000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793382728", "measurement_point": "vibration_rms_x", "value": "1.1226654052734375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T17:52:06.851000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T17:52:06.851000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T17:52:06.851000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793382728", "value": "1.8711090087890625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T17:52:06.851000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T17:52:06.851000+00:00#vibration_rms_y"}, {"vibration_rms": "0.9355545043945312", "timestamp": "2026-09-30T18:52:00.522000+00:00", "GSI1_SK": "METRIC#2026-09-30T18:52:00.522000+00:00", "vibration_peak": "4.041595458984375", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "16.675", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T18:52:00.522000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T18:52:00.522000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "acceleration_rms", "expires_at": "1793386321", "value": "0.83586181640625", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T18:52:00.522000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T18:52:00.522000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T18:52:00.522000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "battery_voltage", "expires_at": "1793386321", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T18:52:00.522000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T18:52:00.522000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T18:52:00.522000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "temperature", "expires_at": "1793386321", "value": "16.675", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T18:52:00.522000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T18:52:00.522000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T18:52:00.522000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793386321", "measurement_point": "vibration_peak", "value": "4.041595458984375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T18:52:00.522000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T18:52:00.522000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T18:52:00.522000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms", "expires_at": "1793386321", "value": "0.9355545043945312", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T18:52:00.522000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T18:52:00.522000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T18:52:00.522000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_x", "expires_at": "1793386321", "value": "1.5343093872070315", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T18:52:00.522000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T18:52:00.522000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T18:52:00.522000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793386321", "measurement_point": "vibration_rms_y", "value": "0.89813232421875", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T18:52:00.522000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T18:52:00.522000+00:00#vibration_rms_y"}, {"vibration_rms": "0.89813232421875", "timestamp": "2026-09-30T19:57:24.598000+00:00", "GSI1_SK": "METRIC#2026-09-30T19:57:24.598000+00:00", "vibration_peak": "3.5551071166992188", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "19.761", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T19:57:24.598000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T19:57:24.598000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "acceleration_rms", "expires_at": "1793390245", "value": "0.97477294921875", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T19:57:24.598000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T19:57:24.598000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T19:57:24.598000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793390245", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T19:57:24.598000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T19:57:24.598000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T19:57:24.598000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793390245", "measurement_point": "temperature", "value": "19.761", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T19:57:24.598000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T19:57:24.598000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T19:57:24.598000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_peak", "expires_at": "1793390245", "value": "3.5551071166992188", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T19:57:24.598000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T19:57:24.598000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T19:57:24.598000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms", "expires_at": "1793390245", "value": "0.89813232421875", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T19:57:24.598000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T19:57:24.598000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T19:57:24.598000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_x", "expires_at": "1793390245", "value": "1.347198486328125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T19:57:24.598000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T19:57:24.598000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T19:57:24.598000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793390245", "value": "1.1600875854492188", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T19:57:24.598000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T19:57:24.598000+00:00#vibration_rms_y"}, {"vibration_rms": "1.758842468261719", "timestamp": "2026-09-30T20:57:19.601000+00:00", "GSI1_SK": "METRIC#2026-09-30T20:57:19.601000+00:00", "battery_voltage": "3.6", "vibration_peak": "4.415817260742188", "PK": "TENANT#brim", "temperature": "18.132", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T20:57:19.601000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T20:57:19.601000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "acceleration_rms", "expires_at": "1793393839", "value": "0.77359130859375", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T20:57:19.601000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T20:57:19.601000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T20:57:19.601000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793393839", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T20:57:19.601000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T20:57:19.601000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T20:57:19.601000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793393839", "measurement_point": "temperature", "value": "18.132", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T20:57:19.601000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T20:57:19.601000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T20:57:19.601000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793393839", "measurement_point": "vibration_peak", "value": "4.415817260742188", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T20:57:19.601000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T20:57:19.601000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T20:57:19.601000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793393839", "measurement_point": "vibration_rms", "value": "1.758842468261719", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T20:57:19.601000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T20:57:19.601000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T20:57:19.601000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_x", "expires_at": "1793393839", "value": "1.459465026855469", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T20:57:19.601000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T20:57:19.601000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T20:57:19.601000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793393839", "measurement_point": "vibration_rms_y", "value": "1.4968872070312502", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T20:57:19.601000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T20:57:19.601000+00:00#vibration_rms_y"}, {"vibration_rms": "1.8336868286132812", "timestamp": "2026-09-30T21:57:13.659000+00:00", "GSI1_SK": "METRIC#2026-09-30T21:57:13.659000+00:00", "battery_voltage": "3.6", "vibration_peak": "4.977149963378906", "PK": "TENANT#brim", "temperature": "17.785", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T21:57:13.659000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T21:57:13.659000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "acceleration_rms", "expires_at": "1793397433", "value": "0.7664062500000001", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T21:57:13.659000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T21:57:13.659000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T21:57:13.659000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "battery_voltage", "expires_at": "1793397433", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T21:57:13.659000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T21:57:13.659000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T21:57:13.659000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "temperature", "expires_at": "1793397433", "value": "17.785", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T21:57:13.659000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T21:57:13.659000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T21:57:13.659000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_peak", "expires_at": "1793397433", "value": "4.977149963378906", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T21:57:13.659000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T21:57:13.659000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T21:57:13.659000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms", "expires_at": "1793397433", "value": "1.8336868286132812", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T21:57:13.659000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T21:57:13.659000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T21:57:13.659000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_x", "expires_at": "1793397433", "value": "1.5343093872070315", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T21:57:13.659000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T21:57:13.659000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T21:57:13.659000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793397433", "value": "1.7962646484375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T21:57:13.659000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T21:57:13.659000+00:00#vibration_rms_y"}, {"vibration_rms": "0.9355545043945312", "timestamp": "2026-09-30T22:56:57.357000+00:00", "GSI1_SK": "METRIC#2026-09-30T22:56:57.357000+00:00", "battery_voltage": "3.6", "vibration_peak": "4.378395080566406", "PK": "TENANT#brim", "temperature": "18.582", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T22:56:57.357000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T22:56:57.357000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793401017", "measurement_point": "acceleration_rms", "value": "0.7472460937500001", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-09-30T22:56:57.357000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T22:56:57.357000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T22:56:57.357000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "battery_voltage", "expires_at": "1793401017", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-09-30T22:56:57.357000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T22:56:57.357000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T22:56:57.357000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "temperature", "expires_at": "1793401017", "value": "18.582", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-09-30T22:56:57.357000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T22:56:57.357000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T22:56:57.357000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_peak", "expires_at": "1793401017", "value": "4.378395080566406", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-09-30T22:56:57.357000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T22:56:57.357000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T22:56:57.357000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793401017", "measurement_point": "vibration_rms", "value": "0.9355545043945312", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-09-30T22:56:57.357000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T22:56:57.357000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T22:56:57.357000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793401017", "measurement_point": "vibration_rms_x", "value": "1.347198486328125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-09-30T22:56:57.357000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T22:56:57.357000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-09-30T22:56:57.357000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793401017", "value": "0.8607101440429689", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-09-30T22:56:57.357000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-09-30T22:56:57.357000+00:00#vibration_rms_y"}, {"vibration_rms": "0.03742218017578125", "timestamp": "2026-10-01T01:56:05.281000+00:00", "GSI1_SK": "METRIC#2026-10-01T01:56:05.281000+00:00", "vibration_peak": "0.11226654052734375", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "15.746", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T01:56:05.281000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T01:56:05.281000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "acceleration_rms", "expires_at": "1793411765", "value": "0.01916015625", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T01:56:05.281000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T01:56:05.281000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T01:56:05.281000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "battery_voltage", "expires_at": "1793411765", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T01:56:05.281000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T01:56:05.281000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T01:56:05.281000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793411765", "measurement_point": "temperature", "value": "15.746", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T01:56:05.281000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T01:56:05.281000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T01:56:05.281000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793411765", "measurement_point": "vibration_peak", "value": "0.11226654052734375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T01:56:05.281000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T01:56:05.281000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T01:56:05.281000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms", "expires_at": "1793411765", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T01:56:05.281000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T01:56:05.281000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T01:56:05.281000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_x", "expires_at": "1793411765", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T01:56:05.281000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T01:56:05.281000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T01:56:05.281000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793411765", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T01:56:05.281000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T01:56:05.281000+00:00#vibration_rms_y"}, {"vibration_rms": "0.03742218017578125", "timestamp": "2026-10-01T04:55:14.538000+00:00", "GSI1_SK": "METRIC#2026-10-01T04:55:14.538000+00:00", "battery_voltage": "3.6", "vibration_peak": "0.11226654052734375", "PK": "TENANT#brim", "temperature": "14.261", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T04:55:14.538000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T04:55:14.538000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "acceleration_rms", "expires_at": "1793422515", "value": "0.01916015625", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T04:55:14.538000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T04:55:14.538000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T04:55:14.538000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793422515", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T04:55:14.538000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T04:55:14.538000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T04:55:14.538000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "temperature", "expires_at": "1793422515", "value": "14.261", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T04:55:14.538000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T04:55:14.538000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T04:55:14.538000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_peak", "expires_at": "1793422515", "value": "0.11226654052734375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T04:55:14.538000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T04:55:14.538000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T04:55:14.538000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms", "expires_at": "1793422515", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T04:55:14.538000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T04:55:14.538000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T04:55:14.538000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793422515", "measurement_point": "vibration_rms_x", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T04:55:14.538000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T04:55:14.538000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T04:55:14.538000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793422515", "measurement_point": "vibration_rms_y", "value": "0.03742218017578125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T04:55:14.538000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T04:55:14.538000+00:00#vibration_rms_y"}, {"vibration_rms": "5.987548828125001", "timestamp": "2026-10-01T09:14:40.766000+00:00", "GSI1_SK": "METRIC#2026-10-01T09:14:40.766000+00:00", "vibration_peak": "12.573852539062502", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "11.925", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T09:14:40.766000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T09:14:40.766000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793438080", "measurement_point": "acceleration_rms", "value": "0.9053173828125001", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T09:14:40.766000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T09:14:40.766000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T09:14:40.766000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "battery_voltage", "expires_at": "1793438080", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T09:14:40.766000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T09:14:40.766000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T09:14:40.766000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793438080", "measurement_point": "temperature", "value": "11.925", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T09:14:40.766000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T09:14:40.766000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T09:14:40.766000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_peak", "expires_at": "1793438080", "value": "12.573852539062502", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T09:14:40.766000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T09:14:40.766000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T09:14:40.766000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms", "expires_at": "1793438080", "value": "5.987548828125001", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T09:14:40.766000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T09:14:40.766000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T09:14:40.766000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793438080", "measurement_point": "vibration_rms_x", "value": "4.041595458984375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T09:14:40.766000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T09:14:40.766000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T09:14:40.766000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793438080", "value": "3.9293289184570312", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T09:14:40.766000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T09:14:40.766000+00:00#vibration_rms_y"}, {"vibration_rms": "1.2723541259765625", "timestamp": "2026-10-01T11:14:27.112000+00:00", "GSI1_SK": "METRIC#2026-10-01T11:14:27.112000+00:00", "vibration_peak": "3.6673736572265625", "battery_voltage": "3.6", "PK": "TENANT#brim", "temperature": "10.734", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T11:14:27.112000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T11:14:27.112000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793445268", "measurement_point": "acceleration_rms", "value": "0.7520361328125", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T11:14:27.112000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T11:14:27.112000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T11:14:27.112000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793445268", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T11:14:27.112000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T11:14:27.112000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T11:14:27.112000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "temperature", "expires_at": "1793445268", "value": "10.734", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T11:14:27.112000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T11:14:27.112000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T11:14:27.112000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_peak", "expires_at": "1793445268", "value": "3.6673736572265625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T11:14:27.112000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T11:14:27.112000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T11:14:27.112000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793445268", "measurement_point": "vibration_rms", "value": "1.2723541259765625", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T11:14:27.112000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T11:14:27.112000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T11:14:27.112000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_x", "expires_at": "1793445268", "value": "1.4968872070312502", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T11:14:27.112000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T11:14:27.112000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T11:14:27.112000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793445268", "measurement_point": "vibration_rms_y", "value": "1.4220428466796877", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T11:14:27.112000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T11:14:27.112000+00:00#vibration_rms_y"}, {"vibration_rms": "1.6465759277343752", "timestamp": "2026-10-01T12:14:13.150000+00:00", "GSI1_SK": "METRIC#2026-10-01T12:14:13.150000+00:00", "battery_voltage": "3.6", "vibration_peak": "5.276527404785156", "PK": "TENANT#brim", "temperature": "10.734", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T12:14:13.150000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T12:14:13.150000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793448853", "measurement_point": "acceleration_rms", "value": "0.75443115234375", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T12:14:13.150000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T12:14:13.150000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T12:14:13.150000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793448853", "measurement_point": "battery_voltage", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T12:14:13.150000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T12:14:13.150000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T12:14:13.150000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "temperature", "expires_at": "1793448853", "value": "10.734", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T12:14:13.150000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T12:14:13.150000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T12:14:13.150000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793448853", "measurement_point": "vibration_peak", "value": "5.276527404785156", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T12:14:13.150000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T12:14:13.150000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T12:14:13.150000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793448853", "measurement_point": "vibration_rms", "value": "1.6465759277343752", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T12:14:13.150000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T12:14:13.150000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T12:14:13.150000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_x", "expires_at": "1793448853", "value": "1.7962646484375", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T12:14:13.150000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T12:14:13.150000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T12:14:13.150000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793448853", "value": "1.758842468261719", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T12:14:13.150000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T12:14:13.150000+00:00#vibration_rms_y"}, {"vibration_rms": "1.5717315673828127", "timestamp": "2026-10-01T15:13:17.873000+00:00", "GSI1_SK": "METRIC#2026-10-01T15:13:17.873000+00:00", "battery_voltage": "3.6", "vibration_peak": "5.126838684082031", "PK": "TENANT#brim", "temperature": "10.25", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T15:13:17.873000+00:00"}, {"unit": "g", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T15:13:17.873000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793459598", "measurement_point": "acceleration_rms", "value": "0.7448510742187501", "tenant_id": "brim", "GSI1_SK": "METRIC#acceleration_rms#2026-10-01T15:13:17.873000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T15:13:17.873000+00:00#acceleration_rms"}, {"unit": "V", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T15:13:17.873000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "battery_voltage", "expires_at": "1793459598", "value": "3.6", "tenant_id": "brim", "GSI1_SK": "METRIC#battery_voltage#2026-10-01T15:13:17.873000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T15:13:17.873000+00:00#battery_voltage"}, {"unit": "\u00b0C", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T15:13:17.873000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "temperature", "expires_at": "1793459598", "value": "10.25", "tenant_id": "brim", "GSI1_SK": "METRIC#temperature#2026-10-01T15:13:17.873000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T15:13:17.873000+00:00#temperature"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T15:13:17.873000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_peak", "expires_at": "1793459598", "value": "5.126838684082031", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_peak#2026-10-01T15:13:17.873000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T15:13:17.873000+00:00#vibration_peak"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T15:13:17.873000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms", "expires_at": "1793459598", "value": "1.5717315673828127", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms#2026-10-01T15:13:17.873000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T15:13:17.873000+00:00#vibration_rms"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T15:13:17.873000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "expires_at": "1793459598", "measurement_point": "vibration_rms_x", "value": "1.8336868286132812", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_x#2026-10-01T15:13:17.873000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T15:13:17.873000+00:00#vibration_rms_x"}, {"unit": "mm/s", "plant_id": "nordurgardur", "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "timestamp": "2026-10-01T15:13:17.873000+00:00", "line_id": "mottokulina", "machine_id": "brim_1", "measurement_point": "vibration_rms_y", "expires_at": "1793459598", "value": "1.347198486328125", "tenant_id": "brim", "GSI1_SK": "METRIC#vibration_rms_y#2026-10-01T15:13:17.873000+00:00", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "SK": "METRIC#b0d9b54f3558#2026-10-01T15:13:17.873000+00:00#vibration_rms_y"}, {"location": "Grandi Reykjav\u00edk", "plant_id": "nordurgardur", "plant_name": "Nor\u00f0urgar\u00f0ur", "GSI1_SK": "PLANT#nordurgardur", "plant_type": "ONSHORE_PROCESSING", "is_vessel": false, "timezone": "UTC", "PK": "TENANT#brim", "GSI1_PK": "PLANT", "SK": "PLANT#nordurgardur"}, {"updated_at": "2026-08-17T07:50:39.647157+00:00", "device_id": "iphone_supervisor_01", "push_token": "ExponentPushToken[xxxxxxxxxxxxxx]", "PK": "TENANT#brim", "platform": "ios", "SK": "PUSH_TOKEN#iphone_supervisor_01"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-29T23:27:54.585324+00:00", "ttl": "1793316474", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790720018531", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "serial": "b0d9b54f3558", "payload": {"temperature": "18.992", "vibration": {"rms": {"x": "1.1600875854492188", "y": "1.7962646484375", "z": "1.347198486328125"}, "a_rms": {"x": "0.71611083984375", "y": "0.5221142578125", "z": "0.737666015625"}, "meas_details": {"sample_rate": "7302"}}, "trigger": "vibration"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790720018531, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 18.992, \"vibration\": {\"rms\": {\"x\": 1.1600875854492188, \"y\": 1.7962646484375, \"z\": 1.347198486328125}, \"a_rms\": {\"x\": 0.71611083984375, \"y\": 0.5221142578125, \"z\": 0.737666015625}, \"meas_details\": {\"sample_rate\": 7302}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790724474585", "SK": "RAWLOG#2026-09-29T23:27:54.585324+00:00#b0d9b54f3558_392c99"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-29T23:27:54.740128+00:00", "ttl": "1793316474", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790719270997", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "serial": "8edbe59e5e78", "payload": {"temperature": "12.718", "vibration": {"rms": {"x": "1.6839981079101565", "y": "1.8711090087890625", "z": "1.4968872070312502"}, "a_rms": {"x": "0.6873706054687501", "y": "1.1927197265625", "z": "0.7137158203125"}, "meas_details": {"sample_rate": "7300"}}, "trigger": "vibration"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790719270997, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 12.718, \"vibration\": {\"rms\": {\"x\": 1.6839981079101565, \"y\": 1.8711090087890625, \"z\": 1.4968872070312502}, \"a_rms\": {\"x\": 0.6873706054687501, \"y\": 1.1927197265625, \"z\": 0.7137158203125}, \"meas_details\": {\"sample_rate\": 7300}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790724474740", "SK": "RAWLOG#2026-09-29T23:27:54.740128+00:00#8edbe59e5e78_abff0c"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T02:01:05.305323+00:00", "ttl": "1793325665", "gateway_id": "", "raw_payload": {"payload": {"trigger": "listen_timeout", "temperature": "10.671", "vibration": {"a_abs_rms": {"min": "0", "max": "0.10059082031250001"}, "rms": {"x": "0.03742218017578125", "z": "0.03742218017578125", "y": "0.03742218017578125"}, "a_rms": {"y": "0.01916015625", "x": "0.01916015625", "z": "0.02155517578125"}, "abs_rms": {"min": "0", "max": "0.11226654052734375"}, "meas_details": {"sample_rate": "7302"}}}, "serial": "8edbe59e5e78", "timestamp_ms": "1790733665201", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790733665201, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"listen_timeout\", \"temperature\": 10.671, \"vibration\": {\"rms\": {\"x\": 0.03742218017578125, \"y\": 0.03742218017578125, \"z\": 0.03742218017578125}, \"a_rms\": {\"x\": 0.01916015625, \"y\": 0.01916015625, \"z\": 0.02155517578125}, \"a_abs_rms\": {\"min\": 0, \"max\": 0.10059082031250001}, \"abs_rms\": {\"min\": 0, \"max\": 0.11226654052734375}, \"meas_details\": {\"sample_rate\": 7302}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790733665305", "SK": "RAWLOG#2026-09-30T02:01:05.305323+00:00#8edbe59e5e78_85cc98"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T02:12:22.735025+00:00", "ttl": "1793326342", "gateway_id": "", "raw_payload": {"serial": "b0d9b54f3558", "timestamp_ms": "1790734342583", "payload": {"trigger": "listen_timeout", "temperature": "15.945", "vibration": {"a_rms": {"z": "0.01916015625", "y": "0.01676513671875", "x": "0.01676513671875"}, "a_abs_rms": {"min": "0", "max": "0.086220703125"}, "rms": {"z": "0.03742218017578125", "x": "0.03742218017578125", "y": "0.03742218017578125"}, "meas_details": {"sample_rate": "7304"}, "abs_rms": {"min": "0", "max": "0.0748443603515625"}}}, "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790734342583, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"listen_timeout\", \"temperature\": 15.945, \"vibration\": {\"rms\": {\"x\": 0.03742218017578125, \"y\": 0.03742218017578125, \"z\": 0.03742218017578125}, \"a_rms\": {\"x\": 0.01676513671875, \"y\": 0.01676513671875, \"z\": 0.01916015625}, \"a_abs_rms\": {\"min\": 0, \"max\": 0.086220703125}, \"abs_rms\": {\"min\": 0, \"max\": 0.0748443603515625}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790734342735", "SK": "RAWLOG#2026-09-30T02:12:22.735025+00:00#b0d9b54f3558_197d01"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T05:00:58.174529+00:00", "ttl": "1793336458", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790744458047", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "serial": "8edbe59e5e78", "payload": {"temperature": "10.367", "vibration": {"rms": {"x": "0.03742218017578125", "y": "0.03742218017578125", "z": "0.03742218017578125"}, "a_rms": {"x": "0.01916015625", "y": "0.01676513671875", "z": "0.02155517578125"}, "a_abs_rms": {"max": "0.08382568359375", "min": "0"}, "abs_rms": {"max": "0.11226654052734375", "min": "0"}, "meas_details": {"sample_rate": "7303"}}, "trigger": "listen_timeout"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790744458047, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"listen_timeout\", \"temperature\": 10.367, \"vibration\": {\"rms\": {\"x\": 0.03742218017578125, \"y\": 0.03742218017578125, \"z\": 0.03742218017578125}, \"a_rms\": {\"x\": 0.01916015625, \"y\": 0.01676513671875, \"z\": 0.02155517578125}, \"a_abs_rms\": {\"min\": 0, \"max\": 0.08382568359375}, \"abs_rms\": {\"min\": 0, \"max\": 0.11226654052734375}, \"meas_details\": {\"sample_rate\": 7303}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790744458174", "SK": "RAWLOG#2026-09-30T05:00:58.174529+00:00#8edbe59e5e78_128d28"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T05:11:33.295878+00:00", "ttl": "1793337093", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790745093166", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "serial": "b0d9b54f3558", "payload": {"temperature": "14.488", "vibration": {"rms": {"x": "0.03742218017578125", "y": "0.03742218017578125", "z": "0.03742218017578125"}, "a_rms": {"x": "0.01676513671875", "y": "0.0143701171875", "z": "0.02155517578125"}, "a_abs_rms": {"max": "0.09340576171875001", "min": "0"}, "abs_rms": {"max": "0.11226654052734375", "min": "0"}, "meas_details": {"sample_rate": "7305"}}, "trigger": "listen_timeout"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790745093166, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"listen_timeout\", \"temperature\": 14.488, \"vibration\": {\"rms\": {\"x\": 0.03742218017578125, \"y\": 0.03742218017578125, \"z\": 0.03742218017578125}, \"a_rms\": {\"x\": 0.01676513671875, \"y\": 0.0143701171875, \"z\": 0.02155517578125}, \"a_abs_rms\": {\"min\": 0, \"max\": 0.09340576171875001}, \"abs_rms\": {\"min\": 0, \"max\": 0.11226654052734375}, \"meas_details\": {\"sample_rate\": 7305}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790745093295", "SK": "RAWLOG#2026-09-30T05:11:33.295878+00:00#b0d9b54f3558_d20685"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T07:54:57.539113+00:00", "ttl": "1793346897", "gateway_id": "", "raw_payload": {"payload": {"vibration": {"rms": {"z": "1.7214202880859377", "y": "2.1704864501953125", "x": "2.207908630371094"}, "a_rms": {"z": "0.74964111328125", "x": "0.72090087890625", "y": "1.140029296875"}, "a_abs_rms": {"max": "4.493056640625", "min": "0"}, "abs_rms": {"max": "6.5114593505859375", "min": "0"}, "meas_details": {"sample_rate": "7303"}}, "trigger": "vibration", "temperature": "9.632"}, "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "timestamp_ms": "1790754897383", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "serial": "8edbe59e5e78"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790754897383, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 9.632, \"vibration\": {\"rms\": {\"x\": 2.207908630371094, \"y\": 2.1704864501953125, \"z\": 1.7214202880859377}, \"a_rms\": {\"x\": 0.72090087890625, \"y\": 1.140029296875, \"z\": 0.74964111328125}, \"a_abs_rms\": {\"min\": 0, \"max\": 4.493056640625}, \"abs_rms\": {\"min\": 0, \"max\": 6.5114593505859375}, \"meas_details\": {\"sample_rate\": 7303}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790754897539", "SK": "RAWLOG#2026-09-30T07:54:57.539113+00:00#8edbe59e5e78_019e44"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T08:54:44.262194+00:00", "ttl": "1793350484", "gateway_id": "", "raw_payload": {"payload": {"trigger": "vibration", "vibration": {"rms": {"y": "2.39501953125", "z": "2.3201751708984375", "x": "1.8336868286132812"}, "a_rms": {"x": "0.7328759765625", "y": "0.5316943359375", "z": "0.7616162109375001"}, "a_abs_rms": {"min": "0", "max": "4.61759765625"}, "abs_rms": {"min": "0", "max": "5.1642608642578125"}, "meas_details": {"sample_rate": "7306"}}, "temperature": "11.785"}, "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "timestamp_ms": "1790758484119", "serial": "b0d9b54f3558", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790758484119, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 11.785, \"vibration\": {\"rms\": {\"x\": 1.8336868286132812, \"y\": 2.39501953125, \"z\": 2.3201751708984375}, \"a_rms\": {\"x\": 0.7328759765625, \"y\": 0.5316943359375, \"z\": 0.7616162109375001}, \"a_abs_rms\": {\"min\": 0, \"max\": 4.61759765625}, \"abs_rms\": {\"min\": 0, \"max\": 5.1642608642578125}, \"meas_details\": {\"sample_rate\": 7306}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "epoch_ms": "1790758484262", "SK": "RAWLOG#2026-09-30T08:54:44.262194+00:00#b0d9b54f3558_00f378"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T08:55:03.198049+00:00", "ttl": "1793350503", "gateway_id": "", "raw_payload": {"mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "serial": "8edbe59e5e78", "timestamp_ms": "1790758503085", "payload": {"temperature": "8.085", "trigger": "vibration", "vibration": {"a_abs_rms": {"max": "4.768483886718751", "min": "0"}, "a_rms": {"y": "1.17116455078125", "z": "0.7280859375000001", "x": "0.9340576171875"}, "rms": {"x": "3.4428405761718754", "y": "3.2931518554687504", "z": "1.758842468261719"}, "meas_details": {"sample_rate": "7304"}, "abs_rms": {"max": "8.943901062011719", "min": "0"}}}, "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790758503085, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 8.085, \"vibration\": {\"rms\": {\"x\": 3.4428405761718754, \"y\": 3.2931518554687504, \"z\": 1.758842468261719}, \"a_rms\": {\"x\": 0.9340576171875, \"y\": 1.17116455078125, \"z\": 0.7280859375000001}, \"a_abs_rms\": {\"min\": 0, \"max\": 4.768483886718751}, \"abs_rms\": {\"min\": 0, \"max\": 8.943901062011719}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790758503198", "SK": "RAWLOG#2026-09-30T08:55:03.198049+00:00#8edbe59e5e78_886cc9"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T09:54:19.634093+00:00", "ttl": "1793354059", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790762059015", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "serial": "b0d9b54f3558", "payload": {"temperature": "10.859", "vibration": {"rms": {"x": "1.5717315673828127", "y": "2.357597351074219", "z": "1.2723541259765625"}, "a_rms": {"x": "0.7280859375000001", "y": "0.51971923828125", "z": "0.70174072265625"}, "a_abs_rms": {"max": "4.26073974609375", "min": "0"}, "abs_rms": {"max": "4.7900390625", "min": "0"}, "meas_details": {"sample_rate": "7307"}}, "trigger": "vibration"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790762059015, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 10.859, \"vibration\": {\"rms\": {\"x\": 1.5717315673828127, \"y\": 2.357597351074219, \"z\": 1.2723541259765625}, \"a_rms\": {\"x\": 0.7280859375000001, \"y\": 0.51971923828125, \"z\": 0.70174072265625}, \"a_abs_rms\": {\"min\": 0, \"max\": 4.26073974609375}, \"abs_rms\": {\"min\": 0, \"max\": 4.7900390625}, \"meas_details\": {\"sample_rate\": 7307}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790762059634", "SK": "RAWLOG#2026-09-30T09:54:19.634093+00:00#b0d9b54f3558_a8d0ba"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T09:54:58.115551+00:00", "ttl": "1793354098", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790762097973", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "serial": "8edbe59e5e78", "payload": {"temperature": "8.058", "vibration": {"rms": {"x": "3.1434631347656254", "y": "3.0311965942382812", "z": "1.8711090087890625"}, "a_rms": {"x": "0.8454418945312501", "y": "1.08494384765625", "z": "0.7065307617187501"}, "a_abs_rms": {"max": "4.4499462890625", "min": "0"}, "abs_rms": {"max": "9.355545043945312", "min": "0"}, "meas_details": {"sample_rate": "7305"}}, "trigger": "vibration"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790762097973, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 8.058, \"vibration\": {\"rms\": {\"x\": 3.1434631347656254, \"y\": 3.0311965942382812, \"z\": 1.8711090087890625}, \"a_rms\": {\"x\": 0.8454418945312501, \"y\": 1.08494384765625, \"z\": 0.7065307617187501}, \"a_abs_rms\": {\"min\": 0, \"max\": 4.4499462890625}, \"abs_rms\": {\"min\": 0, \"max\": 9.355545043945312}, \"meas_details\": {\"sample_rate\": 7305}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790762098115", "SK": "RAWLOG#2026-09-30T09:54:58.115551+00:00#8edbe59e5e78_3c7c66"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T10:55:13.541007+00:00", "ttl": "1793357713", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790765713391", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "serial": "8edbe59e5e78", "payload": {"temperature": "7.617", "vibration": {"rms": {"x": "2.8815078735351562", "y": "2.6195526123046875", "z": "1.4968872070312502"}, "a_rms": {"x": "0.71132080078125", "y": "1.02267333984375", "z": "0.61072998046875"}, "a_abs_rms": {"max": "3.90627685546875", "min": "0"}, "abs_rms": {"max": "7.634124755859375", "min": "0"}, "meas_details": {"sample_rate": "7305"}}, "trigger": "vibration"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790765713391, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 7.617, \"vibration\": {\"rms\": {\"x\": 2.8815078735351562, \"y\": 2.6195526123046875, \"z\": 1.4968872070312502}, \"a_rms\": {\"x\": 0.71132080078125, \"y\": 1.02267333984375, \"z\": 0.61072998046875}, \"a_abs_rms\": {\"min\": 0, \"max\": 3.90627685546875}, \"abs_rms\": {\"min\": 0, \"max\": 7.634124755859375}, \"meas_details\": {\"sample_rate\": 7305}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790765713541", "SK": "RAWLOG#2026-09-30T10:55:13.541007+00:00#8edbe59e5e78_72f700"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T11:54:57.197221+00:00", "ttl": "1793361297", "gateway_id": "", "raw_payload": {"$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "timestamp_ms": "1790769296614", "serial": "8edbe59e5e78", "payload": {"vibration": {"rms": {"x": "2.5821304321289062", "z": "1.2349319458007812", "y": "2.1704864501953125"}, "a_abs_rms": {"max": "5.10378662109375", "min": "0"}, "a_rms": {"z": "0.63228515625", "y": "1.07296875", "x": "0.7137158203125"}, "abs_rms": {"min": "0", "max": "11.63829803466797"}, "meas_details": {"sample_rate": "7304"}}, "trigger": "vibration", "temperature": "8.578"}, "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790769296614, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 8.578, \"vibration\": {\"rms\": {\"x\": 2.5821304321289062, \"y\": 2.1704864501953125, \"z\": 1.2349319458007812}, \"a_rms\": {\"x\": 0.7137158203125, \"y\": 1.07296875, \"z\": 0.63228515625}, \"a_abs_rms\": {\"min\": 0, \"max\": 5.10378662109375}, \"abs_rms\": {\"min\": 0, \"max\": 11.63829803466797}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790769297197", "SK": "RAWLOG#2026-09-30T11:54:57.197221+00:00#8edbe59e5e78_329b5d"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T12:53:34.001497+00:00", "ttl": "1793364814", "gateway_id": "", "raw_payload": {"mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "timestamp_ms": "1790772813477", "serial": "b0d9b54f3558", "payload": {"trigger": "vibration", "temperature": "12.746", "vibration": {"a_rms": {"z": "0.833466796875", "x": "0.97477294921875", "y": "1.0106982421875002"}, "a_abs_rms": {"min": "0", "max": "3.9901025390625002"}, "abs_rms": {"min": "0", "max": "9.392967224121094"}, "rms": {"y": "4.116439819335938", "z": "1.9085311889648438", "x": "3.9293289184570312"}, "meas_details": {"sample_rate": "7305"}}}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790772813477, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 12.746, \"vibration\": {\"rms\": {\"x\": 3.9293289184570312, \"y\": 4.116439819335938, \"z\": 1.9085311889648438}, \"a_rms\": {\"x\": 0.97477294921875, \"y\": 1.0106982421875002, \"z\": 0.833466796875}, \"a_abs_rms\": {\"min\": 0, \"max\": 3.9901025390625002}, \"abs_rms\": {\"min\": 0, \"max\": 9.392967224121094}, \"meas_details\": {\"sample_rate\": 7305}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "epoch_ms": "1790772814001", "SK": "RAWLOG#2026-09-30T12:53:34.001497+00:00#b0d9b54f3558_727c09"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T13:53:10.348823+00:00", "ttl": "1793368390", "gateway_id": "", "raw_payload": {"mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "serial": "b0d9b54f3558", "payload": {"temperature": "13.41", "vibration": {"rms": {"x": "4.266128540039063", "y": "4.004173278808594", "z": "3.7047958374023438"}, "a_rms": {"x": "1.044228515625", "z": "0.8837622070312501", "y": "1.09931396484375"}, "abs_rms": {"max": "11.63829803466797", "min": "0"}, "a_abs_rms": {"min": "0", "max": "4.43318115234375"}, "meas_details": {"sample_rate": "7305"}}, "trigger": "vibration"}, "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "timestamp_ms": "1790776390202"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790776390202, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 13.41, \"vibration\": {\"rms\": {\"x\": 4.266128540039063, \"y\": 4.004173278808594, \"z\": 3.7047958374023438}, \"a_rms\": {\"x\": 1.044228515625, \"y\": 1.09931396484375, \"z\": 0.8837622070312501}, \"a_abs_rms\": {\"min\": 0, \"max\": 4.43318115234375}, \"abs_rms\": {\"min\": 0, \"max\": 11.63829803466797}, \"meas_details\": {\"sample_rate\": 7305}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "epoch_ms": "1790776390348", "SK": "RAWLOG#2026-09-30T13:53:10.348823+00:00#b0d9b54f3558_e45dcc"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T13:55:09.563497+00:00", "ttl": "1793368509", "gateway_id": "", "raw_payload": {"mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "serial": "8edbe59e5e78", "timestamp_ms": "1790776509375", "payload": {"temperature": "8.191", "vibration": {"a_abs_rms": {"min": "0", "max": "3.8775366210937503"}, "rms": {"x": "1.9833755493164065", "z": "1.5717315673828127", "y": "2.2827529907226567"}, "a_rms": {"z": "0.689765625", "x": "0.64905029296875", "y": "1.0873388671875"}, "meas_details": {"sample_rate": "7305"}, "abs_rms": {"max": "7.1102142333984375", "min": "0"}}, "trigger": "vibration"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790776509375, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 8.191, \"vibration\": {\"rms\": {\"x\": 1.9833755493164065, \"y\": 2.2827529907226567, \"z\": 1.5717315673828127}, \"a_rms\": {\"x\": 0.64905029296875, \"y\": 1.0873388671875, \"z\": 0.689765625}, \"a_abs_rms\": {\"min\": 0, \"max\": 3.8775366210937503}, \"abs_rms\": {\"min\": 0, \"max\": 7.1102142333984375}, \"meas_details\": {\"sample_rate\": 7305}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790776509563", "SK": "RAWLOG#2026-09-30T13:55:09.563497+00:00#8edbe59e5e78_fbef43"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T14:55:05.536077+00:00", "ttl": "1793372105", "gateway_id": "", "raw_payload": {"$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "timestamp_ms": "1790780104909", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "serial": "8edbe59e5e78", "payload": {"trigger": "vibration", "temperature": "8.167", "vibration": {"a_abs_rms": {"min": "0", "max": "41.66615478515625"}, "rms": {"x": "4.565505981445313", "z": "1.459465026855469", "y": "1.7214202880859377"}, "a_rms": {"y": "0.71132080078125", "z": "0.7328759765625", "x": "1.93278076171875"}, "abs_rms": {"max": "30.910720825195312", "min": "0"}, "meas_details": {"sample_rate": "7304"}}}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790780104909, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 8.167, \"vibration\": {\"rms\": {\"x\": 4.565505981445313, \"y\": 1.7214202880859377, \"z\": 1.459465026855469}, \"a_rms\": {\"x\": 1.93278076171875, \"y\": 0.71132080078125, \"z\": 0.7328759765625}, \"a_abs_rms\": {\"min\": 0, \"max\": 41.66615478515625}, \"abs_rms\": {\"min\": 0, \"max\": 30.910720825195312}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790780105536", "SK": "RAWLOG#2026-09-30T14:55:05.536077+00:00#8edbe59e5e78_20f945"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T15:52:39.517868+00:00", "ttl": "1793375559", "gateway_id": "", "raw_payload": {"$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "timestamp_ms": "1790783558952", "serial": "b0d9b54f3558", "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "payload": {"temperature": "13.304", "vibration": {"rms": {"y": "1.4220428466796877", "x": "1.3097763061523438", "z": "1.7962646484375"}, "a_rms": {"x": "0.8454418945312501", "z": "0.795146484375", "y": "0.50055908203125"}, "meas_details": {"sample_rate": "7305"}, "abs_rms": {"max": "4.116439819335938", "min": "0"}, "a_abs_rms": {"max": "6.006708984375", "min": "0"}}, "trigger": "vibration"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790783558952, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 13.304, \"vibration\": {\"rms\": {\"x\": 1.3097763061523438, \"y\": 1.4220428466796877, \"z\": 1.7962646484375}, \"a_rms\": {\"x\": 0.8454418945312501, \"y\": 0.50055908203125, \"z\": 0.795146484375}, \"a_abs_rms\": {\"min\": 0, \"max\": 6.006708984375}, \"abs_rms\": {\"min\": 0, \"max\": 4.116439819335938}, \"meas_details\": {\"sample_rate\": 7305}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790783559517", "SK": "RAWLOG#2026-09-30T15:52:39.517868+00:00#b0d9b54f3558_050978"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T15:54:58.965116+00:00", "ttl": "1793375698", "gateway_id": "", "raw_payload": {"$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "serial": "8edbe59e5e78", "timestamp_ms": "1790783698508", "payload": {"trigger": "vibration", "temperature": "9.015", "vibration": {"meas_details": {"sample_rate": "7304"}, "a_abs_rms": {"max": "55.76802978515625", "min": "0"}, "abs_rms": {"max": "44.270439147949226", "min": "0"}, "rms": {"y": "3.218307495117188", "z": "2.09564208984375", "x": "5.987548828125001"}, "a_rms": {"y": "1.2597802734375", "z": "0.9340576171875", "x": "3.03448974609375"}}}, "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790783698508, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 9.015, \"vibration\": {\"rms\": {\"x\": 5.987548828125001, \"y\": 3.218307495117188, \"z\": 2.09564208984375}, \"a_rms\": {\"x\": 3.03448974609375, \"y\": 1.2597802734375, \"z\": 0.9340576171875}, \"a_abs_rms\": {\"min\": 0, \"max\": 55.76802978515625}, \"abs_rms\": {\"min\": 0, \"max\": 44.270439147949226}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790783698965", "SK": "RAWLOG#2026-09-30T15:54:58.965116+00:00#8edbe59e5e78_98fd7a"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T16:52:23.711137+00:00", "ttl": "1793379143", "gateway_id": "", "raw_payload": {"$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "payload": {"vibration": {"rms": {"y": "2.058219909667969", "x": "1.0852432250976562", "z": "1.945953369140625"}, "a_rms": {"y": "0.5221142578125", "z": "0.7879614257812501", "x": "0.83586181640625"}, "a_abs_rms": {"min": "0", "max": "4.914580078125001"}, "abs_rms": {"min": "0", "max": "4.415817260742188"}, "meas_details": {"sample_rate": "7304"}}, "trigger": "vibration", "temperature": "14.906"}, "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "timestamp_ms": "1790787143070", "serial": "b0d9b54f3558"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790787143070, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 14.906, \"vibration\": {\"rms\": {\"x\": 1.0852432250976562, \"y\": 2.058219909667969, \"z\": 1.945953369140625}, \"a_rms\": {\"x\": 0.83586181640625, \"y\": 0.5221142578125, \"z\": 0.7879614257812501}, \"a_abs_rms\": {\"min\": 0, \"max\": 4.914580078125001}, \"abs_rms\": {\"min\": 0, \"max\": 4.415817260742188}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790787143711", "SK": "RAWLOG#2026-09-30T16:52:23.711137+00:00#b0d9b54f3558_d6f957"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T16:55:02.540739+00:00", "ttl": "1793379302", "gateway_id": "", "raw_payload": {"$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "timestamp_ms": "1790787302392", "payload": {"trigger": "vibration", "temperature": "9.656", "vibration": {"a_abs_rms": {"min": "0", "max": "52.996992187500005"}, "abs_rms": {"max": "34.46582794189453", "min": "0"}, "rms": {"z": "2.0207977294921875", "y": "2.918930053710938", "x": "5.9127044677734375"}, "a_rms": {"y": "1.35797607421875", "z": "1.02746337890625", "x": "2.998564453125"}, "meas_details": {"sample_rate": "7303"}}}, "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "serial": "8edbe59e5e78"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790787302392, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 9.656, \"vibration\": {\"rms\": {\"x\": 5.9127044677734375, \"y\": 2.918930053710938, \"z\": 2.0207977294921875}, \"a_rms\": {\"x\": 2.998564453125, \"y\": 1.35797607421875, \"z\": 1.02746337890625}, \"a_abs_rms\": {\"min\": 0, \"max\": 52.996992187500005}, \"abs_rms\": {\"min\": 0, \"max\": 34.46582794189453}, \"meas_details\": {\"sample_rate\": 7303}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790787302540", "SK": "RAWLOG#2026-09-30T16:55:02.540739+00:00#8edbe59e5e78_5334a1"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T17:52:07.359378+00:00", "ttl": "1793382727", "gateway_id": "", "raw_payload": {"$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "serial": "b0d9b54f3558", "payload": {"trigger": "vibration", "temperature": "15.351", "vibration": {"rms": {"y": "1.8711090087890625", "x": "1.1226654052734375", "z": "1.945953369140625"}, "a_abs_rms": {"max": "4.905", "min": "0"}, "abs_rms": {"max": "4.977149963378906", "min": "0"}, "meas_details": {"sample_rate": "7304"}, "a_rms": {"y": "0.51013916015625", "z": "0.7616162109375001", "x": "0.85023193359375"}}}, "timestamp_ms": "1790790726851", "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790790726851, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 15.351, \"vibration\": {\"rms\": {\"x\": 1.1226654052734375, \"y\": 1.8711090087890625, \"z\": 1.945953369140625}, \"a_rms\": {\"x\": 0.85023193359375, \"y\": 0.51013916015625, \"z\": 0.7616162109375001}, \"a_abs_rms\": {\"min\": 0, \"max\": 4.905}, \"abs_rms\": {\"min\": 0, \"max\": 4.977149963378906}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790790727359", "SK": "RAWLOG#2026-09-30T17:52:07.359378+00:00#b0d9b54f3558_601c5d"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T17:54:56.819369+00:00", "ttl": "1793382896", "gateway_id": "", "raw_payload": {"serial": "8edbe59e5e78", "payload": {"trigger": "vibration", "vibration": {"rms": {"y": "2.6569747924804688", "z": "2.09564208984375", "x": "5.239105224609375"}, "a_abs_rms": {"max": "55.514157714843755", "min": "0"}, "a_rms": {"z": "1.36276611328125", "y": "1.6525634765625001", "x": "3.2620166015625003"}, "abs_rms": {"min": "0", "max": "36.52404785156251"}, "meas_details": {"sample_rate": "7303"}}, "temperature": "9.792"}, "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "timestamp_ms": "1790790896280"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790790896280, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 9.792, \"vibration\": {\"rms\": {\"x\": 5.239105224609375, \"y\": 2.6569747924804688, \"z\": 2.09564208984375}, \"a_rms\": {\"x\": 3.2620166015625003, \"y\": 1.6525634765625001, \"z\": 1.36276611328125}, \"a_abs_rms\": {\"min\": 0, \"max\": 55.514157714843755}, \"abs_rms\": {\"min\": 0, \"max\": 36.52404785156251}, \"meas_details\": {\"sample_rate\": 7303}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790790896819", "SK": "RAWLOG#2026-09-30T17:54:56.819369+00:00#8edbe59e5e78_3730bf"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T18:52:01.115609+00:00", "ttl": "1793386321", "gateway_id": "", "raw_payload": {"serial": "b0d9b54f3558", "timestamp_ms": "1790794320522", "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "payload": {"trigger": "vibration", "vibration": {"abs_rms": {"min": "0", "max": "4.041595458984375"}, "a_rms": {"y": "0.49337402343750003", "x": "0.77838134765625", "z": "0.83586181640625"}, "meas_details": {"sample_rate": "7304"}, "a_abs_rms": {"min": "0", "max": "4.5601171875"}, "rms": {"y": "0.89813232421875", "z": "0.9355545043945312", "x": "1.5343093872070315"}}, "temperature": "16.675"}, "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790794320522, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 16.675, \"vibration\": {\"rms\": {\"x\": 1.5343093872070315, \"y\": 0.89813232421875, \"z\": 0.9355545043945312}, \"a_rms\": {\"x\": 0.77838134765625, \"y\": 0.49337402343750003, \"z\": 0.83586181640625}, \"a_abs_rms\": {\"min\": 0, \"max\": 4.5601171875}, \"abs_rms\": {\"min\": 0, \"max\": 4.041595458984375}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "epoch_ms": "1790794321115", "SK": "RAWLOG#2026-09-30T18:52:01.115609+00:00#b0d9b54f3558_45ef8c"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T18:55:01.171098+00:00", "ttl": "1793386501", "gateway_id": "", "raw_payload": {"serial": "8edbe59e5e78", "timestamp_ms": "1790794500594", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "payload": {"trigger": "vibration", "vibration": {"rms": {"z": "1.9085311889648438", "x": "6.3617706298828125", "y": "2.207908630371094"}, "abs_rms": {"min": "0", "max": "26.532325744628906"}, "meas_details": {"sample_rate": "7300"}, "a_rms": {"y": "1.2118798828125001", "z": "0.8669970703125001", "x": "2.38304443359375"}, "a_abs_rms": {"max": "35.9827734375", "min": "0"}}, "temperature": "12.414"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790794500594, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 12.414, \"vibration\": {\"rms\": {\"x\": 6.3617706298828125, \"y\": 2.207908630371094, \"z\": 1.9085311889648438}, \"a_rms\": {\"x\": 2.38304443359375, \"y\": 1.2118798828125001, \"z\": 0.8669970703125001}, \"a_abs_rms\": {\"min\": 0, \"max\": 35.9827734375}, \"abs_rms\": {\"min\": 0, \"max\": 26.532325744628906}, \"meas_details\": {\"sample_rate\": 7300}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790794501171", "SK": "RAWLOG#2026-09-30T18:55:01.171098+00:00#8edbe59e5e78_4c7565"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T19:55:55.976666+00:00", "ttl": "1793390155", "gateway_id": "", "raw_payload": {"payload": {"temperature": "12.476", "trigger": "vibration", "vibration": {"abs_rms": {"max": "0.4116439819335938", "min": "0"}, "a_abs_rms": {"min": "0", "max": "0.19878662109375"}, "a_rms": {"y": "0.052690429687500005", "x": "0.045505371093750004", "z": "0.03113525390625"}, "meas_details": {"sample_rate": "7300"}, "rms": {"y": "0.149688720703125", "x": "0.11226654052734375", "z": "0.0748443603515625"}}}, "timestamp_ms": "1790798155307", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "serial": "8edbe59e5e78", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790798155307, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 12.476, \"vibration\": {\"rms\": {\"x\": 0.11226654052734375, \"y\": 0.149688720703125, \"z\": 0.0748443603515625}, \"a_rms\": {\"x\": 0.045505371093750004, \"y\": 0.052690429687500005, \"z\": 0.03113525390625}, \"a_abs_rms\": {\"min\": 0, \"max\": 0.19878662109375}, \"abs_rms\": {\"min\": 0, \"max\": 0.4116439819335938}, \"meas_details\": {\"sample_rate\": 7300}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790798155976", "SK": "RAWLOG#2026-09-30T19:55:55.976666+00:00#8edbe59e5e78_52c8df"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T19:57:25.113729+00:00", "ttl": "1793390245", "gateway_id": "", "raw_payload": {"serial": "b0d9b54f3558", "timestamp_ms": "1790798244598", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "payload": {"temperature": "19.761", "vibration": {"abs_rms": {"max": "3.5551071166992188", "min": "0"}, "meas_details": {"sample_rate": "7301"}, "a_abs_rms": {"min": "0", "max": "6.5479833984375"}, "a_rms": {"y": "1.063388671875", "x": "1.1256591796875", "z": "0.97477294921875"}, "rms": {"x": "1.347198486328125", "z": "0.89813232421875", "y": "1.1600875854492188"}}, "trigger": "vibration"}, "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790798244598, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 19.761, \"vibration\": {\"rms\": {\"x\": 1.347198486328125, \"y\": 1.1600875854492188, \"z\": 0.89813232421875}, \"a_rms\": {\"x\": 1.1256591796875, \"y\": 1.063388671875, \"z\": 0.97477294921875}, \"a_abs_rms\": {\"min\": 0, \"max\": 6.5479833984375}, \"abs_rms\": {\"min\": 0, \"max\": 3.5551071166992188}, \"meas_details\": {\"sample_rate\": 7301}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790798245113", "SK": "RAWLOG#2026-09-30T19:57:25.113729+00:00#b0d9b54f3558_c7ed4e"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T20:55:49.025470+00:00", "ttl": "1793393749", "gateway_id": "", "raw_payload": {"$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "timestamp_ms": "1790801748890", "serial": "8edbe59e5e78", "payload": {"trigger": "vibration", "temperature": "12.289", "vibration": {"a_abs_rms": {"min": "0", "max": "28.098369140625003"}, "a_rms": {"y": "2.2944287109375003", "x": "2.0357666015625", "z": "0.689765625"}, "rms": {"x": "4.266128540039063", "y": "4.378395080566406", "z": "1.0103988647460938"}, "abs_rms": {"min": "0", "max": "15.642471313476562"}, "meas_details": {"sample_rate": "7300"}}}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790801748890, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 12.289, \"vibration\": {\"rms\": {\"x\": 4.266128540039063, \"y\": 4.378395080566406, \"z\": 1.0103988647460938}, \"a_rms\": {\"x\": 2.0357666015625, \"y\": 2.2944287109375003, \"z\": 0.689765625}, \"a_abs_rms\": {\"min\": 0, \"max\": 28.098369140625003}, \"abs_rms\": {\"min\": 0, \"max\": 15.642471313476562}, \"meas_details\": {\"sample_rate\": 7300}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790801749025", "SK": "RAWLOG#2026-09-30T20:55:49.025470+00:00#8edbe59e5e78_98cedd"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T20:57:19.746894+00:00", "ttl": "1793393839", "gateway_id": "", "raw_payload": {"mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "payload": {"vibration": {"a_abs_rms": {"min": "0", "max": "5.355263671875"}, "abs_rms": {"min": "0", "max": "4.415817260742188"}, "meas_details": {"sample_rate": "7302"}, "a_rms": {"z": "0.77359130859375", "x": "0.8214916992187501", "y": "0.5748046875"}, "rms": {"y": "1.4968872070312502", "x": "1.459465026855469", "z": "1.758842468261719"}}, "temperature": "18.132", "trigger": "vibration"}, "serial": "b0d9b54f3558", "timestamp_ms": "1790801839601"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790801839601, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 18.132, \"vibration\": {\"rms\": {\"x\": 1.459465026855469, \"y\": 1.4968872070312502, \"z\": 1.758842468261719}, \"a_rms\": {\"x\": 0.8214916992187501, \"y\": 0.5748046875, \"z\": 0.77359130859375}, \"a_abs_rms\": {\"min\": 0, \"max\": 5.355263671875}, \"abs_rms\": {\"min\": 0, \"max\": 4.415817260742188}, \"meas_details\": {\"sample_rate\": 7302}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "epoch_ms": "1790801839746", "SK": "RAWLOG#2026-09-30T20:57:19.746894+00:00#b0d9b54f3558_24daee"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T21:55:53.408083+00:00", "ttl": "1793397353", "gateway_id": "", "raw_payload": {"mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "serial": "8edbe59e5e78", "timestamp_ms": "1790805353285", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "payload": {"temperature": "11.617", "trigger": "vibration", "vibration": {"rms": {"y": "2.9937744140625004", "x": "3.4054183959960938", "z": "1.047821044921875"}, "a_rms": {"z": "0.5700146484375", "x": "1.5064672851562502", "y": "1.5328125000000001"}, "a_abs_rms": {"max": "23.24845458984375", "min": "0"}, "meas_details": {"sample_rate": "7301"}, "abs_rms": {"min": "0", "max": "13.022918701171875"}}}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790805353285, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 11.617, \"vibration\": {\"rms\": {\"x\": 3.4054183959960938, \"y\": 2.9937744140625004, \"z\": 1.047821044921875}, \"a_rms\": {\"x\": 1.5064672851562502, \"y\": 1.5328125000000001, \"z\": 0.5700146484375}, \"a_abs_rms\": {\"min\": 0, \"max\": 23.24845458984375}, \"abs_rms\": {\"min\": 0, \"max\": 13.022918701171875}, \"meas_details\": {\"sample_rate\": 7301}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790805353408", "SK": "RAWLOG#2026-09-30T21:55:53.408083+00:00#8edbe59e5e78_727822"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T21:57:13.780187+00:00", "ttl": "1793397433", "gateway_id": "", "raw_payload": {"$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "serial": "b0d9b54f3558", "timestamp_ms": "1790805433659", "payload": {"temperature": "17.785", "vibration": {"rms": {"x": "1.5343093872070315", "y": "1.7962646484375", "z": "1.8336868286132812"}, "a_rms": {"z": "0.7664062500000001", "x": "0.77359130859375", "y": "0.5748046875"}, "abs_rms": {"max": "4.977149963378906", "min": "0"}, "a_abs_rms": {"max": "4.5936474609375", "min": "0"}, "meas_details": {"sample_rate": "7303"}}, "trigger": "vibration"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790805433659, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 17.785, \"vibration\": {\"rms\": {\"x\": 1.5343093872070315, \"y\": 1.7962646484375, \"z\": 1.8336868286132812}, \"a_rms\": {\"x\": 0.77359130859375, \"y\": 0.5748046875, \"z\": 0.7664062500000001}, \"a_abs_rms\": {\"min\": 0, \"max\": 4.5936474609375}, \"abs_rms\": {\"min\": 0, \"max\": 4.977149963378906}, \"meas_details\": {\"sample_rate\": 7303}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790805433780", "SK": "RAWLOG#2026-09-30T21:57:13.780187+00:00#b0d9b54f3558_8c9097"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T22:55:57.928385+00:00", "ttl": "1793400957", "gateway_id": "", "raw_payload": {"$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "serial": "8edbe59e5e78", "timestamp_ms": "1790808957804", "payload": {"temperature": "12.96", "vibration": {"a_abs_rms": {"max": "27.846892089843752", "min": "0"}, "rms": {"y": "4.715194702148438", "x": "3.6673736572265625", "z": "1.8336868286132812"}, "a_rms": {"x": "2.37825439453125", "y": "3.1805859375", "z": "0.8238867187500001"}, "abs_rms": {"max": "20.582199096679688", "min": "0"}, "meas_details": {"sample_rate": "7299"}}, "trigger": "vibration"}, "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790808957804, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 12.96, \"vibration\": {\"rms\": {\"x\": 3.6673736572265625, \"y\": 4.715194702148438, \"z\": 1.8336868286132812}, \"a_rms\": {\"x\": 2.37825439453125, \"y\": 3.1805859375, \"z\": 0.8238867187500001}, \"a_abs_rms\": {\"min\": 0, \"max\": 27.846892089843752}, \"abs_rms\": {\"min\": 0, \"max\": 20.582199096679688}, \"meas_details\": {\"sample_rate\": 7299}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790808957928", "SK": "RAWLOG#2026-09-30T22:55:57.928385+00:00#8edbe59e5e78_0acb7b"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-09-30T22:56:57.474429+00:00", "ttl": "1793401017", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790809017357", "serial": "b0d9b54f3558", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "payload": {"temperature": "18.582", "trigger": "vibration", "vibration": {"abs_rms": {"min": "0", "max": "4.378395080566406"}, "a_abs_rms": {"max": "6.212680664062501", "min": "0"}, "meas_details": {"sample_rate": "7302"}, "a_rms": {"y": "0.488583984375", "z": "0.7472460937500001", "x": "0.69216064453125"}, "rms": {"y": "0.8607101440429689", "z": "0.9355545043945312", "x": "1.347198486328125"}}}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790809017357, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 18.582, \"vibration\": {\"rms\": {\"x\": 1.347198486328125, \"y\": 0.8607101440429689, \"z\": 0.9355545043945312}, \"a_rms\": {\"x\": 0.69216064453125, \"y\": 0.488583984375, \"z\": 0.7472460937500001}, \"a_abs_rms\": {\"min\": 0, \"max\": 6.212680664062501}, \"abs_rms\": {\"min\": 0, \"max\": 4.378395080566406}, \"meas_details\": {\"sample_rate\": 7302}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790809017474", "SK": "RAWLOG#2026-09-30T22:56:57.474429+00:00#b0d9b54f3558_c9f1b7"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/config/config/treon/treongw2/4115563a", "sensor_id": "4115563a", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T00:20:46.544757+00:00", "ttl": "1793406046", "gateway_id": "", "raw_payload": {"time": "2026-10-01T00:20:46.403759Z", "mqtt_topic": "treonconnect/config/config/treon/treongw2/4115563a", "config": {"bluetooth": {"mac": "E8:18:8F:E9:61:0B"}, "ethernet": {"nameservers": ["10.2.160.10", "10.2.160.11"], "mac": "88:0C:E0:DA:85:25", "gateway": "10.101.220.1", "ip": "10.101.220.145", "netmask": "255.255.255.0", "timeservers": ["0.pool.ntp.org", "1.pool.ntp.org", "2.pool.ntp.org", "3.pool.ntp.org"]}, "iotgw": {"wirepas_adapter": null, "telemetry_config": {"interval_m": null}}, "system_manager": {"gateway_reset_timeout_s": "1800", "ping": true, "ping_addresses": ["google.com", "baidu.cn"], "cellular_reset_timeout_s": "900", "ping_interval": "120"}, "blueberry": null, "wifi": {"nameservers": [], "timeservers": [], "netmask": null, "ip": null, "gateway": null, "mac": null}}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"time\": \"2026-10-01T00:20:46.403759Z\", \"config\": {\"blueberry\": null, \"bluetooth\": {\"mac\": \"E8:18:8F:E9:61:0B\"}, \"ethernet\": {\"gateway\": \"10.101.220.1\", \"ip\": \"10.101.220.145\", \"mac\": \"88:0C:E0:DA:85:25\", \"nameservers\": [\"10.2.160.10\", \"10.2.160.11\"], \"netmask\": \"255.255.255.0\", \"timeservers\": [\"0.pool.ntp.org\", \"1.pool.ntp.org\", \"2.pool.ntp.org\", \"3.pool.ntp.org\"]}, \"iotgw\": {\"telemetry_config\": {\"interval_m\": null}, \"wirepas_adapter\": null}, \"system_manager\": {\"cellular_reset_timeout_s\": 900, \"gateway_reset_timeout_s\": 1800, \"ping\": true, \"ping_addresses\": [\"google.com\", \"baidu.cn\"], \"ping_interval\": 120}, \"wifi\": {\"gateway\": null, \"ip\": null, \"mac\": null, \"nameservers\": [], \"netmask\": null, \"timeservers\": []}}, \"mqtt_topic\": \"treonconnect/config/config/treon/treongw2/4115563a\"}", "epoch_ms": "1790814046544", "SK": "RAWLOG#2026-10-01T00:20:46.544757+00:00#4115563a_1b9aad"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T01:55:45.199941+00:00", "ttl": "1793411745", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790819745069", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "serial": "8edbe59e5e78", "payload": {"vibration": {"a_rms": {"z": "0.02155517578125", "y": "0.01676513671875", "x": "0.01916015625"}, "meas_details": {"sample_rate": "7302"}, "a_abs_rms": {"min": "0", "max": "0.09819580078125001"}, "rms": {"y": "0.03742218017578125", "z": "0.03742218017578125", "x": "0.03742218017578125"}, "abs_rms": {"max": "0.0748443603515625", "min": "0"}}, "temperature": "10.519", "trigger": "listen_timeout"}, "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790819745069, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"listen_timeout\", \"temperature\": 10.519, \"vibration\": {\"rms\": {\"x\": 0.03742218017578125, \"y\": 0.03742218017578125, \"z\": 0.03742218017578125}, \"a_rms\": {\"x\": 0.01916015625, \"y\": 0.01676513671875, \"z\": 0.02155517578125}, \"a_abs_rms\": {\"min\": 0, \"max\": 0.09819580078125001}, \"abs_rms\": {\"min\": 0, \"max\": 0.0748443603515625}, \"meas_details\": {\"sample_rate\": 7302}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790819745199", "SK": "RAWLOG#2026-10-01T01:55:45.199941+00:00#8edbe59e5e78_e918c4"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T01:56:05.421707+00:00", "ttl": "1793411765", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790819765281", "serial": "b0d9b54f3558", "payload": {"temperature": "15.746", "vibration": {"meas_details": {"sample_rate": "7304"}, "a_rms": {"z": "0.01916015625", "x": "0.01676513671875", "y": "0.01676513671875"}, "rms": {"y": "0.03742218017578125", "z": "0.03742218017578125", "x": "0.03742218017578125"}, "abs_rms": {"max": "0.11226654052734375", "min": "0"}, "a_abs_rms": {"min": "0", "max": "0.09580078125000001"}}, "trigger": "listen_timeout"}, "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790819765281, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"listen_timeout\", \"temperature\": 15.746, \"vibration\": {\"rms\": {\"x\": 0.03742218017578125, \"y\": 0.03742218017578125, \"z\": 0.03742218017578125}, \"a_rms\": {\"x\": 0.01676513671875, \"y\": 0.01676513671875, \"z\": 0.01916015625}, \"a_abs_rms\": {\"min\": 0, \"max\": 0.09580078125000001}, \"abs_rms\": {\"min\": 0, \"max\": 0.11226654052734375}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "epoch_ms": "1790819765421", "SK": "RAWLOG#2026-10-01T01:56:05.421707+00:00#b0d9b54f3558_d1a7f2"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T04:55:15.051855+00:00", "ttl": "1793422515", "gateway_id": "", "raw_payload": {"$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "serial": "b0d9b54f3558", "timestamp_ms": "1790830514538", "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "payload": {"temperature": "14.261", "trigger": "listen_timeout", "vibration": {"abs_rms": {"min": "0", "max": "0.11226654052734375"}, "a_abs_rms": {"min": "0", "max": "0.09101074218750001"}, "meas_details": {"sample_rate": "7305"}, "a_rms": {"x": "0.01676513671875", "z": "0.01916015625", "y": "0.01676513671875"}, "rms": {"x": "0.03742218017578125", "z": "0.03742218017578125", "y": "0.03742218017578125"}}}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790830514538, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"listen_timeout\", \"temperature\": 14.261, \"vibration\": {\"rms\": {\"x\": 0.03742218017578125, \"y\": 0.03742218017578125, \"z\": 0.03742218017578125}, \"a_rms\": {\"x\": 0.01676513671875, \"y\": 0.01676513671875, \"z\": 0.01916015625}, \"a_abs_rms\": {\"min\": 0, \"max\": 0.09101074218750001}, \"abs_rms\": {\"min\": 0, \"max\": 0.11226654052734375}, \"meas_details\": {\"sample_rate\": 7305}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790830515051", "SK": "RAWLOG#2026-10-01T04:55:15.051855+00:00#b0d9b54f3558_ee4aad"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T04:55:43.887607+00:00", "ttl": "1793422543", "gateway_id": "", "raw_payload": {"mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "payload": {"vibration": {"rms": {"z": "0.03742218017578125", "y": "0.03742218017578125", "x": "0.03742218017578125"}, "abs_rms": {"min": "0", "max": "0.11226654052734375"}, "a_rms": {"x": "0.01916015625", "y": "0.01676513671875", "z": "0.02155517578125"}, "meas_details": {"sample_rate": "7302"}, "a_abs_rms": {"max": "0.10538085937500001", "min": "0"}}, "trigger": "listen_timeout", "temperature": "10.171"}, "timestamp_ms": "1790830543778", "serial": "8edbe59e5e78"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790830543778, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"listen_timeout\", \"temperature\": 10.171, \"vibration\": {\"rms\": {\"x\": 0.03742218017578125, \"y\": 0.03742218017578125, \"z\": 0.03742218017578125}, \"a_rms\": {\"x\": 0.01916015625, \"y\": 0.01676513671875, \"z\": 0.02155517578125}, \"a_abs_rms\": {\"min\": 0, \"max\": 0.10538085937500001}, \"abs_rms\": {\"min\": 0, \"max\": 0.11226654052734375}, \"meas_details\": {\"sample_rate\": 7302}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790830543887", "SK": "RAWLOG#2026-10-01T04:55:43.887607+00:00#8edbe59e5e78_9e7d54"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T06:04:50.190731+00:00", "ttl": "1793426690", "gateway_id": "", "raw_payload": {"mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "payload": {"temperature": "10.312", "trigger": "vibration", "vibration": {"a_rms": {"x": "0.01916015625", "z": "0.02155517578125", "y": "0.01676513671875"}, "a_abs_rms": {"min": "0", "max": "0.08861572265625"}, "abs_rms": {"max": "0.26195526123046875", "min": "0"}, "meas_details": {"sample_rate": "7302"}, "rms": {"x": "0.149688720703125", "y": "0.03742218017578125", "z": "0.03742218017578125"}}}, "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "serial": "8edbe59e5e78", "timestamp_ms": "1790834689604"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790834689604, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 10.312, \"vibration\": {\"rms\": {\"x\": 0.149688720703125, \"y\": 0.03742218017578125, \"z\": 0.03742218017578125}, \"a_rms\": {\"x\": 0.01916015625, \"y\": 0.01676513671875, \"z\": 0.02155517578125}, \"a_abs_rms\": {\"min\": 0, \"max\": 0.08861572265625}, \"abs_rms\": {\"min\": 0, \"max\": 0.26195526123046875}, \"meas_details\": {\"sample_rate\": 7302}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790834690190", "SK": "RAWLOG#2026-10-01T06:04:50.190731+00:00#8edbe59e5e78_e66ce9"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T07:04:54.064442+00:00", "ttl": "1793430294", "gateway_id": "", "raw_payload": {"payload": {"temperature": "10.921", "vibration": {"abs_rms": {"max": "13.846206665039064", "min": "0"}, "a_abs_rms": {"max": "27.5570947265625", "min": "0"}, "a_rms": {"x": "2.1315673828125", "y": "3.08718017578125", "z": "0.8574169921875"}, "rms": {"x": "3.742218017578125", "y": "4.640350341796875", "z": "0.9355545043945312"}, "meas_details": {"sample_rate": "7301"}}, "trigger": "vibration"}, "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "serial": "8edbe59e5e78", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "timestamp_ms": "1790838293524"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790838293524, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 10.921, \"vibration\": {\"rms\": {\"x\": 3.742218017578125, \"y\": 4.640350341796875, \"z\": 0.9355545043945312}, \"a_rms\": {\"x\": 2.1315673828125, \"y\": 3.08718017578125, \"z\": 0.8574169921875}, \"a_abs_rms\": {\"min\": 0, \"max\": 27.5570947265625}, \"abs_rms\": {\"min\": 0, \"max\": 13.846206665039064}, \"meas_details\": {\"sample_rate\": 7301}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790838294064", "SK": "RAWLOG#2026-10-01T07:04:54.064442+00:00#8edbe59e5e78_4f48f3"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T08:04:56.105906+00:00", "ttl": "1793433896", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790841895936", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "payload": {"temperature": "9.429", "vibration": {"rms": {"y": "2.0207977294921875", "x": "2.544708251953125", "z": "0.7484436035156251"}, "a_abs_rms": {"min": "0", "max": "15.368840332031251"}, "abs_rms": {"max": "10.1788330078125", "min": "0"}, "a_rms": {"z": "0.67060546875", "x": "1.0490185546875002", "y": "1.08973388671875"}, "meas_details": {"sample_rate": "7303"}}, "trigger": "vibration"}, "serial": "8edbe59e5e78", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790841895936, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 9.429, \"vibration\": {\"rms\": {\"x\": 2.544708251953125, \"y\": 2.0207977294921875, \"z\": 0.7484436035156251}, \"a_rms\": {\"x\": 1.0490185546875002, \"y\": 1.08973388671875, \"z\": 0.67060546875}, \"a_abs_rms\": {\"min\": 0, \"max\": 15.368840332031251}, \"abs_rms\": {\"min\": 0, \"max\": 10.1788330078125}, \"meas_details\": {\"sample_rate\": 7303}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790841896105", "SK": "RAWLOG#2026-10-01T08:04:56.105906+00:00#8edbe59e5e78_3c2d10"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T09:04:51.544577+00:00", "ttl": "1793437491", "gateway_id": "", "raw_payload": {"serial": "8edbe59e5e78", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "timestamp_ms": "1790845491382", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "payload": {"trigger": "vibration", "temperature": "8.367", "vibration": {"meas_details": {"sample_rate": "7304"}, "a_rms": {"z": "0.62989013671875", "x": "0.63468017578125", "y": "0.5316943359375"}, "abs_rms": {"max": "3.1060409545898438", "min": "0"}, "rms": {"z": "0.6735992431640625", "y": "1.2349319458007812", "x": "1.1226654052734375"}, "a_abs_rms": {"min": "0", "max": "3.6739599609375"}}}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790845491382, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 8.367, \"vibration\": {\"rms\": {\"x\": 1.1226654052734375, \"y\": 1.2349319458007812, \"z\": 0.6735992431640625}, \"a_rms\": {\"x\": 0.63468017578125, \"y\": 0.5316943359375, \"z\": 0.62989013671875}, \"a_abs_rms\": {\"min\": 0, \"max\": 3.6739599609375}, \"abs_rms\": {\"min\": 0, \"max\": 3.1060409545898438}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790845491544", "SK": "RAWLOG#2026-10-01T09:04:51.544577+00:00#8edbe59e5e78_2a3ebf"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T09:14:40.896606+00:00", "ttl": "1793438080", "gateway_id": "", "raw_payload": {"serial": "b0d9b54f3558", "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "timestamp_ms": "1790846080766", "payload": {"vibration": {"rms": {"x": "4.041595458984375", "y": "3.9293289184570312", "z": "5.987548828125001"}, "meas_details": {"sample_rate": "7306"}, "abs_rms": {"min": "0", "max": "12.573852539062502"}, "a_rms": {"z": "0.9053173828125001", "x": "0.8214916992187501", "y": "0.75922119140625"}, "a_abs_rms": {"max": "3.72904541015625", "min": "0"}}, "trigger": "vibration", "temperature": "11.925"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790846080766, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 11.925, \"vibration\": {\"rms\": {\"x\": 4.041595458984375, \"y\": 3.9293289184570312, \"z\": 5.987548828125001}, \"a_rms\": {\"x\": 0.8214916992187501, \"y\": 0.75922119140625, \"z\": 0.9053173828125001}, \"a_abs_rms\": {\"min\": 0, \"max\": 3.72904541015625}, \"abs_rms\": {\"min\": 0, \"max\": 12.573852539062502}, \"meas_details\": {\"sample_rate\": 7306}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790846080896", "SK": "RAWLOG#2026-10-01T09:14:40.896606+00:00#b0d9b54f3558_e5e832"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T11:04:57.737064+00:00", "ttl": "1793444697", "gateway_id": "", "raw_payload": {"payload": {"vibration": {"a_abs_rms": {"min": "0", "max": "3.1063403320312504"}, "a_rms": {"y": "0.55324951171875", "z": "0.57240966796875", "x": "0.5700146484375"}, "abs_rms": {"max": "4.565505981445313", "min": "0"}, "rms": {"x": "1.609153747558594", "y": "1.5343093872070315", "z": "0.89813232421875"}, "meas_details": {"sample_rate": "7305"}}, "temperature": "7.57", "trigger": "vibration"}, "serial": "8edbe59e5e78", "timestamp_ms": "1790852697106", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790852697106, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 7.57, \"vibration\": {\"rms\": {\"x\": 1.609153747558594, \"y\": 1.5343093872070315, \"z\": 0.89813232421875}, \"a_rms\": {\"x\": 0.5700146484375, \"y\": 0.55324951171875, \"z\": 0.57240966796875}, \"a_abs_rms\": {\"min\": 0, \"max\": 3.1063403320312504}, \"abs_rms\": {\"min\": 0, \"max\": 4.565505981445313}, \"meas_details\": {\"sample_rate\": 7305}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "epoch_ms": "1790852697737", "SK": "RAWLOG#2026-10-01T11:04:57.737064+00:00#8edbe59e5e78_1f454c"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T11:14:27.645561+00:00", "ttl": "1793445267", "gateway_id": "", "raw_payload": {"$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "payload": {"vibration": {"abs_rms": {"min": "0", "max": "3.6673736572265625"}, "a_abs_rms": {"min": "0", "max": "6.258186035156251"}, "meas_details": {"sample_rate": "7307"}, "rms": {"y": "1.4220428466796877", "x": "1.4968872070312502", "z": "1.2723541259765625"}, "a_rms": {"z": "0.7520361328125", "y": "0.6035449218750001", "x": "0.85502197265625"}}, "temperature": "10.734", "trigger": "vibration"}, "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "serial": "b0d9b54f3558", "timestamp_ms": "1790853267112"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "PK": "TENANT#brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790853267112, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 10.734, \"vibration\": {\"rms\": {\"x\": 1.4968872070312502, \"y\": 1.4220428466796877, \"z\": 1.2723541259765625}, \"a_rms\": {\"x\": 0.85502197265625, \"y\": 0.6035449218750001, \"z\": 0.7520361328125}, \"a_abs_rms\": {\"min\": 0, \"max\": 6.258186035156251}, \"abs_rms\": {\"min\": 0, \"max\": 3.6673736572265625}, \"meas_details\": {\"sample_rate\": 7307}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "epoch_ms": "1790853267645", "SK": "RAWLOG#2026-10-01T11:14:27.645561+00:00#b0d9b54f3558_7a9db4"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T12:05:01.547967+00:00", "ttl": "1793448301", "gateway_id": "", "raw_payload": {"serial": "8edbe59e5e78", "timestamp_ms": "1790856301329", "payload": {"vibration": {"a_rms": {"x": "1.85853515625", "z": "0.7280859375000001", "y": "0.7424560546875001"}, "meas_details": {"sample_rate": "7304"}, "a_abs_rms": {"min": "0", "max": "56.498510742187506"}, "abs_rms": {"min": "0", "max": "29.151878356933597"}, "rms": {"y": "2.058219909667969", "x": "5.201683044433595", "z": "0.89813232421875"}}, "temperature": "8.027", "trigger": "vibration"}, "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790856301329, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 8.027, \"vibration\": {\"rms\": {\"x\": 5.201683044433595, \"y\": 2.058219909667969, \"z\": 0.89813232421875}, \"a_rms\": {\"x\": 1.85853515625, \"y\": 0.7424560546875001, \"z\": 0.7280859375000001}, \"a_abs_rms\": {\"min\": 0, \"max\": 56.498510742187506}, \"abs_rms\": {\"min\": 0, \"max\": 29.151878356933597}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790856301547", "SK": "RAWLOG#2026-10-01T12:05:01.547967+00:00#8edbe59e5e78_5d63e6"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T12:14:13.290949+00:00", "ttl": "1793448853", "gateway_id": "", "raw_payload": {"payload": {"temperature": "10.734", "trigger": "vibration", "vibration": {"meas_details": {"sample_rate": "7307"}, "a_rms": {"x": "0.69695068359375", "z": "0.75443115234375", "y": "0.6179150390625"}, "rms": {"z": "1.6465759277343752", "x": "1.7962646484375", "y": "1.758842468261719"}, "a_abs_rms": {"max": "5.5420751953125", "min": "0"}, "abs_rms": {"max": "5.276527404785156", "min": "0"}}}, "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "serial": "b0d9b54f3558", "timestamp_ms": "1790856853150", "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790856853150, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 10.734, \"vibration\": {\"rms\": {\"x\": 1.7962646484375, \"y\": 1.758842468261719, \"z\": 1.6465759277343752}, \"a_rms\": {\"x\": 0.69695068359375, \"y\": 0.6179150390625, \"z\": 0.75443115234375}, \"a_abs_rms\": {\"min\": 0, \"max\": 5.5420751953125}, \"abs_rms\": {\"min\": 0, \"max\": 5.276527404785156}, \"meas_details\": {\"sample_rate\": 7307}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790856853290", "SK": "RAWLOG#2026-10-01T12:14:13.290949+00:00#b0d9b54f3558_ea4222"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T13:05:16.297035+00:00", "ttl": "1793451916", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790859916151", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "serial": "8edbe59e5e78", "payload": {"trigger": "vibration", "temperature": "7.585", "vibration": {"meas_details": {"sample_rate": "7304"}, "a_rms": {"z": "0.57240966796875", "x": "0.5867797851562501", "y": "0.5460644531250001"}, "abs_rms": {"max": "4.528083801269531", "min": "0"}, "a_abs_rms": {"min": "0", "max": "2.6297314453125002"}, "rms": {"z": "0.6735992431640625", "y": "1.4968872070312502", "x": "1.2723541259765625"}}}, "mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790859916151, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 7.585, \"vibration\": {\"rms\": {\"x\": 1.2723541259765625, \"y\": 1.4968872070312502, \"z\": 0.6735992431640625}, \"a_rms\": {\"x\": 0.5867797851562501, \"y\": 0.5460644531250001, \"z\": 0.57240966796875}, \"a_abs_rms\": {\"min\": 0, \"max\": 2.6297314453125002}, \"abs_rms\": {\"min\": 0, \"max\": 4.528083801269531}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790859916297", "SK": "RAWLOG#2026-10-01T13:05:16.297035+00:00#8edbe59e5e78_00aa38"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T14:05:02.367092+00:00", "ttl": "1793455502", "gateway_id": "", "raw_payload": {"mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "payload": {"temperature": "7.578", "vibration": {"rms": {"x": "1.1600875854492188", "z": "0.6735992431640625", "y": "1.3097763061523438"}, "a_abs_rms": {"min": "0", "max": "3.0057495117187503"}, "a_rms": {"z": "0.6059399414062501", "y": "0.55564453125", "x": "0.5652246093750001"}, "meas_details": {"sample_rate": "7305"}, "abs_rms": {"min": "0", "max": "4.303550720214844"}}, "trigger": "vibration"}, "timestamp_ms": "1790863502226", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "serial": "8edbe59e5e78"}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790863502226, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 7.578, \"vibration\": {\"rms\": {\"x\": 1.1600875854492188, \"y\": 1.3097763061523438, \"z\": 0.6735992431640625}, \"a_rms\": {\"x\": 0.5652246093750001, \"y\": 0.55564453125, \"z\": 0.6059399414062501}, \"a_abs_rms\": {\"min\": 0, \"max\": 3.0057495117187503}, \"abs_rms\": {\"min\": 0, \"max\": 4.303550720214844}, \"meas_details\": {\"sample_rate\": 7305}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790863502367", "SK": "RAWLOG#2026-10-01T14:05:02.367092+00:00#8edbe59e5e78_a98c28"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/8edbe59e5e78", "sensor_id": "8edbe59e5e78", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T15:04:57.697161+00:00", "ttl": "1793459097", "gateway_id": "", "raw_payload": {"mqtt_topic": "treonconnect/data/treon/indnodec/8edbe59e5e78", "serial": "8edbe59e5e78", "timestamp_ms": "1790867097599", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "payload": {"trigger": "vibration", "temperature": "7.675", "vibration": {"a_abs_rms": {"max": "2.5674609375", "min": "0"}, "meas_details": {"sample_rate": "7304"}, "rms": {"z": "0.5613327026367188", "y": "1.347198486328125", "x": "1.1600875854492188"}, "abs_rms": {"max": "3.1808853149414062", "min": "0"}, "a_rms": {"z": "0.5316943359375", "x": "0.5748046875", "y": "0.5412744140625"}}}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"8edbe59e5e78\", \"timestamp_ms\": 1790867097599, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 7.675, \"vibration\": {\"rms\": {\"x\": 1.1600875854492188, \"y\": 1.347198486328125, \"z\": 0.5613327026367188}, \"a_rms\": {\"x\": 0.5748046875, \"y\": 0.5412744140625, \"z\": 0.5316943359375}, \"a_abs_rms\": {\"min\": 0, \"max\": 2.5674609375}, \"abs_rms\": {\"min\": 0, \"max\": 3.1808853149414062}, \"meas_details\": {\"sample_rate\": 7304}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/8edbe59e5e78\"}", "PK": "TENANT#brim", "epoch_ms": "1790867097697", "SK": "RAWLOG#2026-10-01T15:04:57.697161+00:00#8edbe59e5e78_0601c1"}, {"entity_type": "RAW_INGRESS_LOG", "path": "mqtt:treonconnect/data/treon/indnodec/b0d9b54f3558", "sensor_id": "b0d9b54f3558", "user_agent": "TreonConnect/IoT-Core", "timestamp": "2026-10-01T15:13:18.063595+00:00", "ttl": "1793459598", "gateway_id": "", "raw_payload": {"timestamp_ms": "1790867597873", "$schema": "https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json", "mqtt_topic": "treonconnect/data/treon/indnodec/b0d9b54f3558", "serial": "b0d9b54f3558", "payload": {"temperature": "10.25", "vibration": {"abs_rms": {"max": "5.126838684082031", "min": "0"}, "rms": {"y": "1.347198486328125", "z": "1.5717315673828127", "x": "1.8336868286132812"}, "a_abs_rms": {"min": "0", "max": "6.5958837890625"}, "meas_details": {"sample_rate": "7307"}, "a_rms": {"x": "0.85502197265625", "y": "0.5604345703125", "z": "0.7448510742187501"}}, "trigger": "vibration"}}, "client_ip": "aws-iot-core", "tenant_id": "brim", "raw_body_str": "{\"serial\": \"b0d9b54f3558\", \"timestamp_ms\": 1790867597873, \"$schema\": \"https://schema.treonconnect.com/data/treon/indnodec/sensordata/1.0.0.json\", \"payload\": {\"trigger\": \"vibration\", \"temperature\": 10.25, \"vibration\": {\"rms\": {\"x\": 1.8336868286132812, \"y\": 1.347198486328125, \"z\": 1.5717315673828127}, \"a_rms\": {\"x\": 0.85502197265625, \"y\": 0.5604345703125, \"z\": 0.7448510742187501}, \"a_abs_rms\": {\"min\": 0, \"max\": 6.5958837890625}, \"abs_rms\": {\"min\": 0, \"max\": 5.126838684082031}, \"meas_details\": {\"sample_rate\": 7307}}}, \"mqtt_topic\": \"treonconnect/data/treon/indnodec/b0d9b54f3558\"}", "PK": "TENANT#brim", "epoch_ms": "1790867598063", "SK": "RAWLOG#2026-10-01T15:13:18.063595+00:00#b0d9b54f3558_662f45"}, {"GSI1_SK": "METADATA", "model": "Treon Industrial Node C", "PK": "TENANT#brim", "asset_id": "brim_2", "GSI1_PK": "SENSOR#8edbe59e5e78", "SK": "SENSOR#8edbe59e5e78"}, {"GSI1_SK": "METADATA", "model": "Treon Industrial Node C", "PK": "TENANT#brim", "asset_id": "brim_1", "GSI1_PK": "SENSOR#b0d9b54f3558", "critical_rms": "4.5", "component": "Drive Motor Bearing", "machine_id": "brim_1", "part_number": "", "critical_temp": "70", "warning_temp": "51", "warning_rms": "2.8", "SK": "SENSOR#b0d9b54f3558"}, {"last_updated": "2026-10-01T00:20:46.655823+00:00", "plant_id": "akureyri_plant", "status": "NORMAL", "estimated_rul_weeks": "10", "line_id": "line_filleting_01", "machine_id": "asset_01", "department_id": "dept_filleting", "shift_name": "Night Shift (Inactive)", "last_rms_z": "0", "last_temp": "42.5", "GSI1_SK": "STATE", "is_operating_window": false, "metrics": {"battery_voltage": "3.6", "vibration_rms": "0", "temperature": "42.5"}, "PK": "TENANT#brim", "run_state": "IDLE", "GSI1_PK": "SENSOR#4115563a", "SK": "STATE#4115563a"}, {"last_updated": "2026-10-01T15:04:57.879885+00:00", "last_rms_z": "0.5613327026367188", "last_temp": "7.675", "status": "NORMAL", "GSI1_SK": "STATE", "estimated_rul_weeks": "10", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#8edbe59e5e78", "plant_id": "nordurgardur", "line_id": "mottokulina", "machine_id": "brim_2", "department_id": "mottaka", "shift_name": "Evening Standby", "is_operating_window": false, "metrics": {"temperature": "7.675", "vibration_peak": "3.1808853149414062", "vibration_rms": "0.5613327026367188", "battery_voltage": "3.6", "vibration_rms_y": "1.347198486328125", "acceleration_rms": "0.5316943359375", "vibration_rms_x": "1.1600875854492188"}, "run_state": "IDLE", "SK": "STATE#8edbe59e5e78"}, {"last_updated": "2026-10-01T15:13:18.230953+00:00", "last_rms_z": "1.5717315673828127", "last_temp": "10.25", "status": "NORMAL", "GSI1_SK": "STATE", "estimated_rul_weeks": "6", "PK": "TENANT#brim", "GSI1_PK": "SENSOR#b0d9b54f3558", "metrics": {"vibration_peak": "5.126838684082031", "vibration_rms_x": "1.8336868286132812", "temperature": "10.25", "vibration_rms_y": "1.347198486328125", "battery_voltage": "3.6", "vibration_rms": "1.5717315673828127", "acceleration_rms": "0.7448510742187501"}, "plant_id": "nordurgardur", "line_id": "mottokulina", "machine_id": "brim_1", "department_id": "mottaka", "shift_name": "Evening Standby", "is_operating_window": false, "run_state": "IDLE", "SK": "STATE#b0d9b54f3558"}, {"GSI1_PK": "USER", "GSI1_SK": "METADATA", "PK": "TENANT#brim", "email": "info@brim.is", "full_name": null, "is_created": false, "is_on_duty": true, "is_superadmin": false, "must_change_password": false, "phone_number": "+3548622107", "receive_email": true, "receive_sms": true, "role": "COMPANY_ADMIN", "tenant_id": "brim", "username": "admin_brim", "SK": "USER#admin_brim"}, {"created_at": "2026-08-19T11:59:57.256387+00:00", "role": "VIEWER", "tenant_id": "brim", "GSI1_SK": "USER#gestur", "username": "gestur", "full_name": "Gestur Sko\u00f0andi", "PK": "TENANT#brim", "email": "gestur@brim.is", "GSI1_PK": "USER", "SK": "USER#gestur"}, {"created_at": "2026-08-19T14:03:30.141088+00:00", "role": "MAINTENANCE_ENGINEER", "tenant_id": "brim", "GSI1_SK": "USER#olafur_taekni", "username": "olafur_taekni", "full_name": "\u00d3lafur T\u00e6knistj\u00f3ri", "PK": "TENANT#brim", "email": "olafur@example.com", "GSI1_PK": "USER", "must_change_password": true, "updated_at": "2026-08-21T07:35:04.476418+00:00", "SK": "USER#olafur_taekni"}, {"is_on_duty": true, "must_change_password": true, "receive_sms": true, "email": "vaktstjori@brim.is", "role": "MAINTENANCE_ENGINEER", "is_created": false, "receive_email": true, "GSI1_SK": "METADATA", "phone_number": "+3548991234", "username": "vaktstjori_01", "PK": "TENANT#brim", "GSI1_PK": "USER", "SK": "USER#vaktstjori_01"}, {"last_updated": "2026-09-30T18:10:17.973972+00:00", "status_level": "WARNING", "created_at": "2026-09-30T13:53:20.977439+00:00", "action_plan": ["1. **LOTO & SAFETY**: Turn Main Infeed Conveyor Breaker Switch 4B (Panel M1) to OFF and attach physical padlock. Verify zero-energy state with calibrated multimeter on motor terminals U1, V1, W1 (0V AC). Place mechanical lock wedge under infeed belt drive sprocket [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "2. **SPARE PARTS**: Procure Marel Drive Drum Bearing Kit No. **M-GRD-6205-KIT** containing SKF **6205-2RSH** deep groove ball bearing (25\u00d752\u00d715 mm), stainless steel labyrinth splash deflector disc **M-DEF-25-SS**, and two high-temp EPDM O-rings (48.0\u00d72.5 mm) from **Shelf B-04** [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "3. **REMOVAL & REPLACEMENT**: Remove bearing housing end-cap fasteners (4\u00d7 M8\u00d725) using cross-diagonal pattern. Extract worn SKF 6205-2RSH bearing and inspect shaft for radial runout (tolerance < **0.04 mm**). Clean bearing cavity with food-grade solvent, install new bearing with stainless splash disc seated flush at **1.0 mm clearance** for 80-bar washdown protection, and apply **Mobil SHC 627** (ISO VG 460 synthetic, NSF H1) lubricant [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "4. **TORQUES & ALIGNMENT**: Torque bearing housing end-cap fasteners to **24 Nm** in cross-diagonal pattern. Verify motor foot mounting bolts (4\u00d7 M12\u00d750 A4-80) at **75 Nm**. Perform optical laser alignment check; radial offset must be < **0.05 mm** [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "5. **STARTUP & VERIFICATION**: Remove LOTO padlock and mechanical wedge. Run infeed conveyor at full speed for 15 minutes under no-load condition. Measure baseline vibration RMS with calibrated sensor (target < **2.5 mm/s**). Document final vibration reading, confirm smooth operation, and sign off work order completion."], "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "status": "VERIFIED_CLOSED", "spare_part": "Drive Motor Bearing (PN: SKF-6205-2RSH)", "assignee": "admin_proceon", "asset_name": "Drive Motor Bearing", "priority": "P2 URGENT", "machine_id": "brim_1", "asset_id": "brim_1", "wo_id": "wo-1790776400977", "tenant_id": "brim", "machine_name": "Brim 1 (Main Grader Drive Motor)", "alerting_sensors": ["b0d9b54f3558"], "GSI1_SK": "WORKORDER#2026-09-30T13:53:20.977439+00:00", "ai_diagnostics": "Vibration RMS at 3.70 mm/s exceeds safe operating threshold, indicating advanced bearing wear on the infeed conveyor drive drum. Remaining useful life is 1.8 weeks; immediate replacement required to prevent catastrophic failure and production bottleneck. No historical maintenance records exist for this bearing assembly, suggesting first-time failure or extended service interval.", "PK": "TENANT#brim", "GSI1_PK": "MACHINE#brim_1", "closed_at": "2026-09-30T18:10:17.973972+00:00", "technician_feedback": "Replaced Drive Motor Bearing (PN: SKF-6205-2RSH). Outer race inspected and confirmed baseline restored.", "verification_outcome": "FALSE_POSITIVE", "actual_root_cause": "BEARING_WEAR", "SK": "WORKORDER#wo-1790776400977"}, {"last_updated": "2026-10-01T11:42:29.628144+00:00", "status_level": "CRITICAL", "created_at": "2026-10-01T09:14:53.425247+00:00", "action_plan": ["1. **LOTO & SAFETY**: Turn Main Infeed Conveyor Breaker Switch **4B** (Panel M1) to OFF, attach padlock, and verify 0V AC on motor terminals U1, V1, W1 [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "2. **SPARE PARTS**: Retrieve Marel Infeed Drive Drum Bearing Kit **M-GRD-6205-KIT** (SKF 6205-2RSH + Splash Deflector M-DEF-25-SS) from warehouse **Shelf B-04** [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "3. **REMOVAL & REPLACEMENT**: Disassemble infeed drum housing, inspect shaft runout (< 0.04 mm), seat splash disc with **1.0 mm** clearance, and apply Mobil SHC 627 food-grade grease [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "4. **TORQUES & ALIGNMENT**: Torque motor foot bolts (M12) to **75 Nm**, end-caps (M8) to **24 Nm**, and belt tensioners to **35 Nm**. Verify radial alignment < 0.05 mm [Ref: M2000 Weight Grader User Manual, Sec 3.2, p. 44].", "5. **STARTUP & VERIFICATION**: Remove LOTO, run empty for 10 minutes, and verify Treon vibration RMS drops below 2.5 mm/s on sensor b0d9b54f3558."], "component": "Drive Motor Bearing", "sensor_id": "b0d9b54f3558", "status": "APPROVED (ASSIGNED)", "asset_name": "Drive Motor Bearing", "assignee": "admin_proceon", "spare_part": "Drive Motor Bearing (PN: SKF-6205-2RSH)", "priority": "P1 URGENT", "machine_id": "brim_1", "asset_id": "brim_1", "wo_id": "wo-1790846093425", "tenant_id": "brim", "machine_name": "Brim 1 (Main Grader Drive Motor)", "alerting_sensors": ["b0d9b54f3558"], "GSI1_SK": "WORKORDER#2026-10-01T09:14:53.425247+00:00", "ai_diagnostics": "Telemetry monitoring on Brim 1 (Main Grader Drive Motor) (Drive Motor Bearing) on sensor b0d9b54f3558 detected elevated degradation (Vibration RMS: 5.99 mm/s). Remaining Useful Life (RUL) projection indicates ~0.0 weeks to failure. Prioritized as P1 to prevent unscheduled plant downtime.", "PK": "TENANT#brim", "GSI1_PK": "MACHINE#brim_1", "SK": "WORKORDER#wo-1790846093425"}], "total_count": 477, "table_name": "ProceonCore", "use_mock": false}